| Sign In | Join Free | My benadorassociates.com |
|
| Categories | Variable Frequency Converter |
|---|---|
| Brand Name: | COENG |
| Model Number: | HD8000 |
| Certification: | CE |
| Place of Origin: | China |
| MOQ: | 1 |
| Payment Terms: | L/C, T/T, Western Union |
| Supply Ability: | 20000sets/year |
| Delivery Time: | 10-30working days |
| Packaging Details: | Wooden Case |
| Rated voltage of grid side: | 2: 1900V 3: 3300V 6: 6600V A: 10kV |
| Rated voltage of motor side: | 3: 3300V 6: 6600V A: 10kV |
| Power: | 10: 10MVA |
| Rectification method: | P: PWM D: Diode basic rectification |
| Common bus rectification method: | Blank: single rectification 2: double rectification |
| Common bus inverter method:: | Blank: single D: double inverter T: triple inverter |
| Company Info. |
| SHENZHEN COENG TECH CO., LTD. |
| Verified Supplier |
| View Contact Details |
| Product List |
HD8000 Medium Voltage Engineering VFD System High power VFD system Variable Frequency Drive Converter
HD8000 Medium Voltage Engineering VFD System High power VFD system Variable Frequency Drive Converter
Product Introduction
| HD8000 Technical Specifications | ||||||||||||||
| HD8000 | 3306 | 3308 | 3310 | 3312 | 2624 | AA30 | 6640 | AA60 | ||||||
| R Basical ectification | Input voltage | 3300V | 1900V | 10kV | 6600V | 10kV | ||||||||
| Input frquency | 45Hz-66Hz | |||||||||||||
| Overload | 110%@ rated current, 120%@ rated current 60s | |||||||||||||
| Efficiency | ≥99% | |||||||||||||
| Power factor | ≥0.95 (Rated current, equipped with 2% AC input reactor) | |||||||||||||
| Protection | overload protection, overheat protection, short circuit protection, fault pre-judgment, etc | |||||||||||||
| RecPWM tification | Input frquency | 45Hz-66Hz | ||||||||||||
| Overload | 110%@ rated current, 120%@ rated current 60s | |||||||||||||
| Efficiency | ≥98.5% | |||||||||||||
| Power factor | adjustable (default 1) | |||||||||||||
| Protection | overload protection, overheat protection, short circuit protection, fault pre-judgment, etc | |||||||||||||
| Inverter | Output voltage | 3300V | 6600V | 10kV | 6600V | 10kV | ||||||||
| Max output frequency | 110Hz | |||||||||||||
| Speed stable accuracy | OLVC: 0.01%, CLVC: 0.01% | OLVC: 0.01%, CLVC: 0.01% | ||||||||||||
| Speed pulse | OLVC: 0.2%, CLVC: 0.1% | OLVC: 0.4%, CLVC: 0.2% | ||||||||||||
| Start torque | OLVC: 150%, CLVC: 200% | OLVC: 130%, CLVC: 150% | ||||||||||||
| Torque control | V/F: Yes, OLVC: Yes, CLVC: Yes | V/F: Yes, OLVC: Yes, CLVC: Yes | ||||||||||||
| Torque accuracy | OLVC: 5%, CLVC: 2% | OLVC: 5%, CLVC: 2% | ||||||||||||
| Torque response time | OLVC: 5ms, CLVC: 5ms | OLVC: 5ms, CLVC: 5ms | ||||||||||||
| Rotating response time | OLVC: 100ms, CLVC: 100ms | OLVC: 150ms, CLVC: 150ms | ||||||||||||
| Dynamic drop equivalent | OLVC: 0.5%*s, CLVC: 0.25%*s | OLVC: 1%*s, CLVC: 0.5%*s | ||||||||||||
| Overload | 110%@rated current, 120%@rated current 60s | |||||||||||||
| Environment | Temperature | inlet temperature ≤40 | ||||||||||||
| Altitude | ≤4000m (2000m~4000m de-rating) | |||||||||||||
| Mechanical Data | IP protection | IP54 | ||||||||||||
| Cooling | Water cooling | |||||||||||||
| Anti corrosion | C4-M | |||||||||||||
| HD8000 Series Selection Table | ||||||||||||||
| Module | Grid Voltage | Motor Voltage | Power | RatedI | Max f | Size (W*D*H) (mm) | Note | |||||||
| HD8000-3306 | 3300V | 3300V | 6MVA | 1050A | 110Hz | 4600*1300*2200 | Contains water cool cabinet | |||||||
| HD8000-3308 | 8MVA | 1400A | ||||||||||||
| HD8000-3310 | 10MVA | 1750A | ||||||||||||
| HD8000-3312 | 12MVA | 2100A | ||||||||||||
| HD8000-2624 | 1900V | 6600V | 24MVA | 2100A | 7800*1300*2200 | |||||||||
| HD8000-AA30 | 10kV | 10kV | 30MVA | 1750A | 10600*1300*2200 | |||||||||
| HD8000-6640 | 6600V | 6600V | 40MVA | 3500A | 15600*1300*2200 | |||||||||
| HD8000-AA60 | 10kV | 10kV | 60MVA | 3500A | 21200*1600*2200 | |||||||||

|