| Sign In | Join Free | My benadorassociates.com | 
 | 
| Categories | Load Switch | 
|---|---|
| Brand Name: | TIANAN | 
| Place of Origin: | CHINA | 
| Model Number: | FZW28F-12 | 
| Certification: | IEC&GB | 
| MOQ: | 1 SET | 
| Price: | Pending | 
| Delivery Time: | 30 work days/ unit | 
| Packaging Details: | Wooden case | 
| Output Voltage: | 3.3V | 
| Ambient temperature: | -40 ~55℃ | 
| Altitude: | ≤2000m | 
| Max. daily temperature difference: | 25k | 
| Rated voltage: | 12kV | 
| Rated frequency: | 50Hz | 
| Rated current: | 630A | 
| mechanical life: | 10000 times | 
| Company Info. | 
| Ningbo Tianan (Group) Co.,Ltd. | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
When there is a fault in the internal user of the T connection of
the 10KV distribution line, if the fault occurs at the incoming
end, or if the fault occurs inside the incoming switch but the
protection action time limit is not coordinated with the protection
of the substation outgoing switch, it will cause the protection of
the substation outgoing switch to trip. If the nature of the fault
is permanent and the substation fails to coincide, an accident
within a medium voltage user boundary will result in a power outage
of the entire distribution line, and even single-phase grounding
will cause interference to other users. This common ripple accident
in the distribution network will cause unnecessary power outage
losses to other normal users and have a negative impact on a
society highly dependent on power supply.
The boundary load switch is an ideal device for solving the
above-mentioned accidents. The device is installed at the
responsibility boundary point of the 10kV distribution line and can
automatically cut off single-phase grounding faults and isolate
phase to phase short circuit faults. Ensure the electrical safety
of non faulty users and prevent malfunctions
The user's accident has escalated. The boundary load switch control
device is specifically designed for intelligent control of the
boundary switch body. To achieve protection and control functions,
the control device is electrically connected to the switch body
through control cables and aviation connectors, realizing its
protection and automatic monitoring functions. This product is
widely used in urban and rural 10kV distribution user lines.
| Rated peak withstand current | 50 kA | 
| Rated short-circuit closing current (peak) | 50 kA | 
| Clearance between open contacts | 9±1 | 
| Altitude | Up To 3,000m Above Sea Level | 
| Opening time | 20~70 ms | 
| Isolation fracture distance | 25~30 ms | 
| Isolation fracture overtravel | 7~14 ms | 
| Three phase opening and closing asynchrony | ≤3 ms | 
| Rated pressure of SF6 gas (gauge pressure) | 0 Mpa | 
|   | 
 40.5KV High Voltage Load Break Switch
                                                                                    
                        
                        
                        
                                                            40.5KV High Voltage Load Break Switch
                                                    
                        
                     12kv Vacuum Load Break Switch
                                                                                    
                        
                        
                        
                                                            12kv Vacuum Load Break Switch
                                                    
                        
                     12KV Outdoor High Voltage Load Switch Circuit Breaker Combined Apparatus
                                                                                    
                        
                        
                        
                                                            12KV Outdoor High Voltage Load Switch Circuit Breaker Combined Apparatus
                                                    
                        
                     12 Kv outdoor Load Switch / High Voltage Disconnect Switch For Electric Power System
                                                                                    
                        
                        
                        
                                                            12 Kv outdoor Load Switch / High Voltage Disconnect Switch For Electric Power System
                                                    
                        
                     TIANAN Double Power Automatic Transfer Switch Relief Delay Time Device
                                                                                    
                        
                        
                        
                                                            TIANAN Double Power Automatic Transfer Switch Relief Delay Time Device
                                                    
                        
                     10KV AIternative Current Vacuum Load Switch Fuse Combined Apparatus
                                                                                    
                        
                        
                        
                                                            10KV AIternative Current Vacuum Load Switch Fuse Combined Apparatus
                                                    
                        
                     Indoor High Voltage Load Switch MCCB Structure Vacuum Load Break Switch
                                                                                    
                        
                        
                        
                                                            Indoor High Voltage Load Switch MCCB Structure Vacuum Load Break Switch
                                                    
                        
                     12kv ACB  Indoor AC Load Switch / Sf6 Load Break Switch With 4 Poles
                                                                                    
                        
                        
                        
                                                            12kv ACB  Indoor AC Load Switch / Sf6 Load Break Switch With 4 Poles
                                                    
                        
                     TIANAN Surge Arrester Medium Voltage 12 KV For Railway , HV Load Switch
                                                                                    
                        
                        
                        
                                                            TIANAN Surge Arrester Medium Voltage 12 KV For Railway , HV Load Switch
                                                    
                        
                     Smart Compact Switch with 1A Output Current and 3.3V Output Voltage
                                                                                    
                        
                        
                        