| Sign In | Join Free | My benadorassociates.com | 
              
  | 
      
| Categories | Stationary Meter Test Bench | 
|---|---|
| Brand Name: | GENY | 
| Model Number: | YC1891D | 
| Certification: | ISO, CE | 
| Place of Origin: | CHINA | 
| Payment Terms: | L/C, T/T, D/P | 
| Supply Ability: | 100/Year | 
| Model NO.: | YC1891D | 
| After-sales Service: | 3 Year | 
| Warranty: | 1 Year | 
| Application: | Electromagnetic Instrument | 
| Power: | Electricity | 
| Voltage Output: | 24V-300V(or Customized) | 
| Current Output: | 1mA-120A/200A | 
| Thermocouple (TC): | No | 
| Resistance-Temperature Detector (RTD): | No | 
| LCD Display: | With LCD Display | 
| Customized: | Customized | 
| Trademark: | GENY | 
| Transport Package: | Plywood Case | 
| Specification: | 10.7CBM | 
| Origin: | China | 
| HS Code: | 9030849000 | 
| Port: | Guangzhou, China | 
| Company Info. | 
| Guangzhou GENY Electric Co., Ltd | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
Our sophisticated meter assessment system is engineered to evaluate a broad spectrum of meters, encompassing mechanical, electromechanical, and electronic types, with the flexibility for fully automated, semi-automated, or manual control. It is capable of assessing single-phase meters configured in 1P2W setups and provides an array of assessment methods such as active power, reactive power, and interlaced reactive power.
| YC1891D-6 | YC1891D-12 | YC1891D-24 | YC1891D-48 | |
| Number of meter positions | 6 | 12 | 24 | 48 | 
| Accuracy | 0.05 | |||
| Power Source | YCS-101-250 | YCS-101-600 | YCS-101-1200 | YCS-101-2500 | 
| Standard Meter | SZ01A-K3 | |||
| MSVT | HJ200GL-6 | HJ200GL-12 | HJ200GL-24 | HJ200GL-48 | 
| QCD | D5 series | |||
| Scanning Head | YCG-2 series | |||
| Voltage | ||||
| Test voltage output | 24V – 288V or customized | |||
| Power of the voltage output | 100VA | 250VA | 500VA | 1000VA | 
| Resolution | Better than 0.01% of full scale value of range | |||
| Setting accuracy | Better than 0.05% at the final range value | |||
| Stability | Better than 0.005%/h (integration time 150 s) | |||
| Load regulation from 0-max. load | Better than 0.01% | |||
| Distortion factor | Better than 0.3% for linear resistance load | |||
| Harmonics | 2nd – 21st free programmable | |||
| Current | ||||
| Test current output | 1mA – 100A or customized,Max.200A | 1mA – 100A | ||
| Power of the current output | 150VA | 350VA | 750VA | 1500VA | 
| Resolution | Better than 0.01% of full scale value of range | |||
| Setting accuracy | Better than 0.05% at the final range value | |||
| Stability | Better than 0.005%/h (integration time 150 s) | |||
| Load regulation from 0-max. load | Better than 0.01% | |||
| Distortion factor | Better than 0.3% for linear resistance load | |||
| Harmonics | 2nd – 21st free programmable | |||
| Phase angle | ||||
| Range | 0 -- 360° | |||
| Resolution | 0.01° | |||
| Setting accuracy | 0.1° | |||
| Frequency | ||||
| Range | 45Hz – 65Hz | |||
| Resolution | 0.01Hz | |||
| Error display | ||||
| Type of error display | Red LED | |||
| Resolution of the error displays | 8 digits | |||
| Voltage Supply | 220V±10% or customized 50/60Hz±2Hz  | 3x220/380V±10% or customized 50/60Hz±2Hz  | ||
| Ambient temperature | -10°C -- +40°C | |||
| Relative humidity | 35% -- 85% | |||

                                 
                             |