| Sign In | Join Free | My benadorassociates.com |
|
| Categories | SF6 Recovery System |
|---|---|
| Brand Name: | KSTONE |
| Model Number: | KSLH-18Y54100 |
| Certification: | ISO9001 |
| Place of Origin: | shanghai |
| MOQ: | 1 |
| Price: | &12000-15000 |
| Supply Ability: | 1000set/year |
| Delivery Time: | 10 work days |
| Packaging Details: | Fumigation wooden box |
| Type: | Freeze liquefied, air-cooled, hand-pushed mobile |
| Working temperature: | -10 ℃~40 ℃ |
| Initial pressure: | 0.8 MPa |
| Recovery final pressure: | ≤ 0.053 MPa |
| Time required for 1m³ volume: | ≤ 0.5 h/m³ |
| Annual leakage rate: | ≤ 1% |
| SF6 moisture content after recycling: | ≤ 60 PPM/V |
| Gas purity and oil content: | ≤ 10 PPM/G |
| Company Info. |
| Shanghai Kstone S&T Development Co .,LTD. |
| Verified Supplier |
| View Contact Details |
| Product List |
Manual operation, basic SF6 recovery device, working voltage three-phase 230V 60Hz
KSLH-18Y54100 (23060Hz)
Suitable for single-phase 110V regions such as the United States, Canada, Mexico, Cuba, Panama, Jamaica, Bolivia, Ecuador, etc
Suitable for 60Hz
1.Main technical performance parameters
| Performance Parameters of the Device | Details |
|---|---|
| Type | Freeze liquefied, air-cooled, hand-pushed mobile |
| Working environment temperature | -10 ℃~40 ℃ |
| Initial pressure (MPa) | 0.8 |
| Recovery final pressure (MPa) | ≤ 0.053 |
| Time required for 1m³ volume (h/m³) * | ≤ 0.5 |
| Initial pressure (Pa) | ≤ 133 |
| Inflation final pressure (MPa) | 0.7 |
| Time required for 1m³ volume (h/m³) | ≤ 0.2 |
| Vacuumizing from 0.1MPa to 133Pa takes time (h/m³) ** | ≤ 1.0 |
| Ultimate vacuum (Pa) | ≤ 10 |
| Vacuum maintained at 133Pa for 24 hours with an increase value (Pa) | ≤ 400 |
| Annual leakage rate | ≤ 1% |
| SF6 moisture content after recycling (PPM/V)*** | ≤ 60 |
| Gas purity and oil content (PPM/G) | ≤ 10 |
| Storage method | Liquid |
| Storage pressure (MPa) | 8 |
| Capacity (L) | 100 |
| Gas storage capacity (kg) | 100 |
| Drying filter regeneration method | Vacuum heating activation regeneration |
2. Power supply three-phase four wire system 3 Φ 230V
| Parameter | Specification |
|---|---|
| Total power (kW) | ≤ 10 |
| Noise dB (A) | ≤ 75 |
3. Main component performance parameters
| Parameter | Details |
|---|---|
| Form | Semi enclosed |
| Theoretical displacement | 18 m³/h |
| Maximum exhaust pressure | 3.5 MPa |
| Allowable exhaust pressure | 3.0 MPa |
| SF6 compressor | |
| Minimum allowable suction pressure | 53 KPa |
| Maximum allowable suction pressure | 1.0 MPa |
| Maximum exhaust temperature | 130 ℃ |
| Power | 2.2 kW |
| Power supply | 3 Φ 230V 60Hz |
| Extraction rate | 15 L/s |
| Vacuum pump ultimate vacuum | ≤ 15 Pa |
| Lubricating oil | HD25 refrigeration oil |
| Container | |
| Category | 2 |
| Design pressure | 8 MPa |
| Design temperature | 45 ℃ |
| Capacity | 100 L |
| Storage capacity | 100 kg |
4. Transportation parameters
| Item | Details |
|---|---|
| Packaging | Fumigation wooden box |
| Dimensions | 1600 * 830 * 1200 |
| Gross weight | 570kg |

|