| Sign In | Join Free | My benadorassociates.com |
|
| Categories | Smoke Toxicity Test |
|---|---|
| Brand Name: | GOLD |
| Model Number: | GD-IEC60754 |
| Certification: | ISO/CE |
| Place of Origin: | China |
| MOQ: | 1set |
| Price: | USD 3000-4000/set |
| Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
| Supply Ability: | 5sets/Month |
| Delivery Time: | 30days |
| Packaging Details: | Standard Wooden Case |
| Name: | Wire and cable Corrosion testing equipment |
| Standard: | IEC60754-1,2 |
| Power: | AC 220V, 50/60Hz, 21A |
| Accuracy: | 0.1L/min |
| Ambient Temperature: | Operating 10℃ to 35℃ |
| Quartz tube: | 40 * 800 |
| Installation size: | 2300 mm (W) * 600 mm (D) |
| Flow meter range: | 0-3L/min |
| Company Info. |
| Chongqing gold mechnical and electrical equipment Co., Ltd |
| Verified Supplier |
| View Contact Details |
| Product List |
IEC60754-1 Corrosion Testing IEC60754-2 Wire And Cable Halogen Acid Gas Release Tester
IEC60754 Wire And Cable Corrosion Tester Product Introduction:
The halogen acid gas release measuring device is designed and manufactured according to the test methods GB/T 17650 and IEC 60754-1/2. It is used to test the halogen gas content, pH value (hydrogen ion content), conductivity, etc. released by wires and cables during combustion. It can also be expanded to EN 50305 and BS 6853 Appendix B for smoke toxicity testing. It complies with the standards: GB/T 17650.1~2-1998, IEC 60754-1/2-1994, EN 50305, BS 6853 Appendix B and other test standards.
IEC60754 Wire And Cable Corrosion Tester Standards:
• GB/T 17650.1~2
• IEC 60754- 1~2

IEC60754 Wire And Cable Corrosion Tester Technical Specification:
Cable Corrosion Tester | |
Standard | IEC 60754-1, 2 |
Dimension | 1500mm(W)*500mm(D)*600mm(H) |
Weight | about 60kg |
Ambient Temperature | Operating 10℃ to 35℃ |
power | 110V AC 60Hz / 230V AC 50Hz, 15A |

IEC60754 Wire And Cable Corrosion Tester Features:
1. The mass flow meter adjusts the air flow rate, with a range of
0-3L/min, and displays the air flow rate numerically, and can be
precisely adjusted with an adjustment accuracy of 0.1L/min;
2. Equipped with an air filter device, including 1 activated carbon
and 1 silica gel filter column;
3. Contains two temperature control modes, one is the program
heating mode, and the other is the single-point heating mode. Both
use PID temperature control mode. Users can choose according to the
test convenience;
4. Over-temperature protection device, when the temperature of the
tube furnace exceeds 1100 degrees, it can automatically cut off the
heating to protect the furnace body;
5. The openable tube furnace device is convenient for users to
clean and replace the quartz heating tube;
6. The imported thermoelectric tube furnace device is used, which
has excellent product performance and longer product life;
7. Equipped with auxiliary devices such as magnetic stirrer, pH
meter and conductivity tester.

|