| Sign In | Join Free | My benadorassociates.com |
|
| Categories | Temperature Test Chamber |
|---|---|
| Brand Name: | SPR-ing |
| Model Number: | JC330 |
| Certification: | GB2423.1、 GB2423.2、 GJB150.3、GJB150.4、GB11158、GB10589 |
| Place of Origin: | Shenzhen |
| MOQ: | 1 piece |
| Price: | 15000~50000 USD |
| Payment Terms: | T/T |
| Supply Ability: | 20/month |
| Delivery Time: | 1~3 weeks |
| Packaging Details: | Wooden carton |
| Nominal internal volume (L): | 330~2000 |
| Temperature range: | -70~220℃ |
| Heating speed: | 3~6℃/min |
| Cooling speed: | 2~3.5℃/min |
| Thermal compensation capability: | 1500~3000W |
| Cooling method: | Air/water cooled (optional) |
| Power supply mode: | AC380V±10% 50Hz 3/N/PE |
| Maximum power: | 15.5kw |
| Maximum current: | 30A |
| Company Info. |
| Shenzhen SPRing Technology Co.,Ltd |
| Verified Supplier |
| View Contact Details |
| Product List |
JC330 high and low temperature test chamber

Air Flow Field Diagram in the Box Unique Air Circulation System and Software Control System
Product characteristics
Model | JT330(C) | JT610(C) | JT1000(C) | JT1500(C) | JT2000(C) | ||
Nominal internal volume (L) | 330L | 610L | 1000L | 1500L | 2000L | ||
Internal dimension (mm) | D | 760 | 795 | 960 | 1470 | 1670 | |
W | 585 | 800 | 1100 | 1100 | 1100 | ||
H | 750 | 950 | 950 | 950 | 1100 | ||
External dimensions (mm) | D | 1820 | 1850 | 2000 | 2525 | 2700 | |
W | 880 | 1100 | 1450 | 1450 | 1430 | ||
H | 1950 | 2230 | 2230 | 2230 | 2400 | ||
Performance parameters | Minimum temperature | ℃ | Minimum temperature of tail band C -70 ℃/minimum temperature of no C -40 ℃ | ||||
Maximum temperature | ℃ | + 180 ° C (the maximum temperature can be up to 220 ° C according to the actual needs of users) | |||||
Temperature fluctuation | ℃ | ±0.1℃~±0.5℃ | |||||
Temperature uniformity | ℃ | ≦2℃(≤150℃) | |||||
Temperature deviation | ℃ | ≦±2℃ | |||||
Heating rate | ℃/min | 4.0 | 6.0 | 4.0 | 4.0 | 3.0 | |
Cooling rate | ℃/min | 3.5 | 2.6 | 2.8 | 2.5 | 2.0 | |
Test method | The above indexes are measured under no-load and ambient temperature of 20 ± 2 ℃ (according to GB/T 5170.2-2017). The temperature and humidity performance test is based on the standard IEC 60068 3-5, and the sensor is placed at the air outlet of the air handling unit. | ||||||
Meet the criteria | GB2423.1, GB2423.2, GJB150.3,GJB150.4,GB11158,GB10589 | ||||||
Thermal compensation capability | 1500~3000W | ||||||
Cooling method | Air/water cooled (optional) | ||||||
Power supply mode | AC380V±10% 50Hz 3/N/PE | ||||||
Maximum power | KW | 4.8 | 8.5 | 11.5 | 11.5 | 15.5 | |
Maximum current | A | 12.3 | 14.8 | 22 | 22 | 30 | |
Noise level | Db(A) | 65 | 65 | 68 | 68 | 70 | |
Equipment weight | KG | 480 | 615 | 870 | 1000 | 1250 | |
|