| Sign In | Join Free | My benadorassociates.com |
|
| Categories | IFM Pressure Sensor |
|---|---|
| Brand Name: | IFM |
| Model Number: | TAD981 |
| Certification: | 3C |
| Place of Origin: | GERMANY |
| MOQ: | 1 |
| Price: | 500$/piece |
| Payment Terms: | T/T |
| Supply Ability: | 1piece in stock |
| Delivery Time: | 3 day |
| Packaging Details: | 103 x 45 x 46mm |
| Measuring range: | -25...160 °C -13...320 °F |
| Pressure rating: | 50 bar 5 MPa |
| Probe length L[mm]: | 33 |
| Protection: | IP 68; IP 69K |
| Company Info. |
| Xiamen ZhiCheng Automation Technology Co., Ltd |
| Verified Supplier |
| View Contact Details |
| Product List |
| Application | |||||||||
| Measuring element | 1 x Pt 1000 + 1 x NTC; (thermically coupled, with backup function (temperature measuring even if one element fails)) | ||||||||
| Media | liquids and gases | ||||||||
| Pressure rating [bar] | 50 | ||||||||
| Minimum installation depth [mm] | 25 | ||||||||
| Electrical data | |||||||||
| Operating voltage [V] | 18...32 DC; ("supply class 2" tocULus) | ||||||||
| Current consumption | [mA] | 6; (24 V) | |||||||
| Protection class | III | ||||||||
| Reverse polarity protection | yes | ||||||||
| Power-on delay time [s] 8 Integrated watchdog yes | |||||||||
| Inputs / outputs | |||||||||
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 | ||||||||
| ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — TAD981-03 — 30.05.2017 | |||||||||
| TAD981 | |||||||||
| Temperature transmitter | |||||||||
| TAD033KLES30-A-ZKG/US | |||||||||
| Outputs | |||||||||
| Total number of outputs | 2 | ||||||||
| Output signal | switching signal; analogue signal; IO-Link; (configurable) | ||||||||
| Electrical design | PNP/NPN | ||||||||
| Number of digital outputs | 1 | ||||||||
| Output function | normally open / normally closed / diagnostic signal; (parameterisable) | ||||||||
| Max. voltage drop switching output DC | [V] | 2 | |||||||
| Permanent current rating of switching output DC | [mA] | 150; (200 (...60°C); 250 (...40 °C)) | |||||||
| Diagnostic output | diagnostic output for drift and fault monitoring | ||||||||
| Number of analogue outputs | 1 | ||||||||
| Analogue current output | [mA] | 4...20 | |||||||
| Max. load | [Ω] | (Ub - 15 V) x 50 | |||||||
| Short-circuit protection | yes | ||||||||
| Type of short-circuit protection | pulsed | ||||||||
| Overload | protection | yes | |||||||
| Measuring/setting range | |||||||||
| Measuring range | -25...160 °C | -13...320 °F | |||||||
| Note on measuring range | scalable | ||||||||
| Factory setting | 0...150 °C / 32...302 °F | ||||||||
| Drift warning | 0.2...5 °C | 0.4...9 °F | |||||||
| Drift alarm | 0.2...5 °C | 0.4...9 °F | |||||||
| Insteps of | 0.05 °C | 0.1 °F | |||||||
| Resolution | |||||||||
| Resolution of analogue | [K] | 0.05 | |||||||
| output | |||||||||
| Accuracy / deviations | |||||||||
| Precision analogue output | [K] | ± 0,2 (-10...130°C); ± 0,3 (130...140°C); ± 0,3 ± 0,1% MS
(-25...-10/140...160°C); (probe completely inserted into the measured medium up to the sealing chamfer) | |||||||
| Temperature coefficient [% of the span / 10 K] | < ± 0,01; (in case of deviation from the reference condition 25 ± 5 °C) | ||||||||
| Response times | |||||||||
| Dynamic response T05 / T09 [s] | 3 / 6 | ||||||||
| Software / programming | |||||||||
| Parameter setting options | drift warning/drift alarm threshold; Fail-Safe; Display unit;
scaling of the analogue output; redundancy switching; performance diagnostic output; switching logic; normally open / normally closed | ||||||||
| ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — TAD981-03 — 30.05.2017 | |||||||||
| TAD981 | |||||||||
| Temperature transmitter | |||||||||
| TAD033KLES30-A-ZKG/US | |||||||||
| Interfaces | |||||||||
| Communication interface | IO-Link | ||||||||
| Transmission type | COM1 (4,8 kBaud) | ||||||||
| IO-Link revision | 1.1 | ||||||||
| SDCI standard | IEC 61131-9 CDV | ||||||||
| IO-Link device ID | 323 d / 00 01 43 h | ||||||||
| Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | ||||||||
| SIO mode | yes | ||||||||
| Required master port type | A | ||||||||
| Process data analogue | 1 | ||||||||
| Process data binary | 1 | ||||||||
| Min. process cycle time [ms] | 18.8 | ||||||||
| Operating conditions | |||||||||
| Ambient temperature [°C] | -25...70 | ||||||||
| Storage temperature [°C] -40...85 Protection IP 68; IP 69K | |||||||||
| Tests / approvals | |||||||||
| EMC | DIN EN 61000-6-2 | ||||||||
| DIN EN 61000-6-3 | |||||||||
| Shock resistance | DIN EN 68000-2-27 | 50 g (11 ms) | |||||||
| Vibration resistance | DIN EN 60068-2-6 | 20 g (10...2000 Hz) | |||||||
| MTTF [years] | 213 | ||||||||
| Note on approval | Including free 5-point calibration certificate. | ||||||||
| Mechanical data | |||||||||
| Weight | [g] | 399 | |||||||
| Materials | stainless steel (1.4404 / 316L); PEI; FKM | ||||||||
| Materials (wetted parts) | stainless steel (1.4404 / 316L) | ||||||||
| Process connection | threaded connection G 1 external thread Aseptoflex Vario | ||||||||
| Surface characteristics Ra/Rz of the wetted parts | Ra: < 0.6 | ||||||||
| Installation length EL [mm] | 33 | ||||||||
| Remarks | |||||||||
| Remarks | MS = set measuring span | ||||||||
| Pack quantity | 1 pcs. | ||||||||
| Electrical connection | |||||||||
| Connector: 1 x M12; Contacts: gold-plated | |||||||||
|