Sign In | Join Free | My benadorassociates.com
benadorassociates.com
Products
Search by Category
Home > General Industrial Equipment Stock >

40 Ton Air Cooled Scroll Type Water Chiller 144KW Air Cooled Industrial System for Extrusion Machine

Categories Portable Water Chiller
Brand Name: ANGES/SZAGS
Model Number: ACK-40(F)
Certification: CE/ISO9001
Place of Origin: China
MOQ: 1
Price: Negotiation
Payment Terms: T/T, L/C
Supply Ability: 600 sets/ month
Delivery Time: 10-35 days
Packaging Details: Plywood case
Type: Air Cooled Sroll Type
Capacity: 40Ton
Compressor typetype: Danfoss/Panosonic/Copeland/LG
Refrigerant: R410A/R407C/R134A/R22
Condenser: finned copper tube + low noise outer rotor fan
Water tank: 345L/620L
Voltage: 3PH~220V/440V/460V/480V~560HZ
Dimension(l*w*h): 2300*1800*2150MM
Weight: 1250kg
Temperature range: 5℃ ~ 35℃
Application: Plastic & Rubber Machinery (injection machine, extruding machine, bottle blowing machine), daily-use chemical, laser cutting machine, PCB machine, electroplating, equipment of laboratory, chemical, polyurethane Foam ,pharmacy and many other areas.
Compressor type: Scroll type
After-sales provided: 24hours Online support/Video technical support/Overseas third-party support available and etc.
Condition: New brand
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

40 Ton Air Cooled Scroll Type Water Chiller 144KW Air Cooled Industrial System for Extrusion Machine

40 Ton Air Cooled Scroll Type Water Chiller 144KW Air Cooled Industrial System for Extrusion Machine

The Benefits of Using SZAGS/ANGES Chillers:

  • Reliable Cooling: Our chillers provide dependable and consistent cooling, ensuring stable operating temperatures for various industrial processes and equipment.

  • Energy Efficiency: Featuring advanced energy-saving technologies, SZAGS/ANGES chillers reduce energy consumption and lower operating expenses.

  • Precise Temperature Control: With precise temperature regulation, our chillers maintain optimal conditions for your specific applications, enhancing product quality and consistency.

  • Extended Equipment Life: By controlling temperatures effectively, our chillers prevent overheating, protect sensitive equipment, and extend its lifespan while reducing maintenance requirements.

  • Eco-Friendly Performance: Designed with environmentally-friendly refrigerants, SZAGS/ANGES chillers contribute to sustainability by minimizing greenhouse gas emissions and protecting the ozone layer.

How to select the model of the chiller?


1. Determine Cooling Load:
Calculate the required cooling load for your application, expressed in tons of refrigeration (TR) or kilowatts (kW). Account for factors such as space size, heat generated by equipment, and external environmental conditions.

2. Type of Chiller:

  • Air-cooled chillers: Ideal for smaller applications, easy to install and maintain.
  • Water-cooled chillers: More efficient for larger applications but require cooling towers, additional space, and higher maintenance.

3. Application and Environment:
Evaluate whether the chiller is intended for industrial processes, comfort cooling, or other applications. Consider the ambient temperature and environmental conditions at the installation site.

4. Energy Efficiency:
Select chillers with a high Coefficient of Performance (COP) or Energy Efficiency Ratio (EER). Models with variable speed drives (VSD) can optimize energy usage and improve efficiency.

5. Capacity Control:
Ensure the chiller can adjust its capacity to meet varying cooling loads. This feature enhances energy savings and overall efficiency.

6. Size and Footprint:
Confirm that the chiller’s size and footprint align with the available installation space.

7. Initial and Operating Costs:
Weigh the initial purchase price against long-term operating costs, including energy use and maintenance. Evaluate the total cost of ownership over the equipment’s lifespan.

8. Reliability and Maintenance:
Choose a chiller known for reliability and ease of maintenance. Check for good service support and the availability of spare parts.

9. Regulatory Compliance:
Verify that the chiller adheres to local regulations and standards, particularly those concerning environmental impact.

10. Manufacturer and Warranty:
Opt for reputable manufacturers that offer robust after-sales service, support, and comprehensive warranties.



Specification

Item Model

ACK-40(F)
nominal cooling capacitykcal/h124253
kw144.48
input powerkw39.52
power supply3PH 440V 60Hz
refrigeranttypeR407C
type of controlthermostatic expansion valve
compressortypehermetic scroll
power(kw)32.4
condensertypefinned copper tube + low noise outer rotor fan
power(kw)3.12
cooling air flow(m3/h)50000
evaporatortypeshell and tube
chilled fluid flow(m3/h)24.91
volume(L)345
inlet and outlet pipe diameter (inch)3
pumppower(kw)4
lift(m)22
safety protectioncompressor overheating protection, over-current protection, high and low pressure protection, over-temperature protection,flow switch protection, phase sequence or missing phase protection, exhaust overheating protection
weightkg1250
dimensionmm2300*1800*2150

Note: The nominal cooling capacity is according to: Inlet chilled fluid temperature: 17℃,outlet chilled fluid temperature: 12℃.


    FAQ

    1. How does a chiller system work?

    A chiller system operates with two separate circulations: one for process water and the other for refrigerant gas. The process water circulates through the system, absorbing heat from the application or process it is cooling. This heat is then transferred to the refrigerant, which circulates through the cooling system. The refrigerant absorbs the heat and carries it to either an air or water-cooled condenser, where the heat is expelled to the surroundings. This continuous process maintains a consistent cooling effect.


    2.How to calculate cooling capacity for chillers?

    Cooling Capacity(kw)= Flow Rate(m3/h)*Temp Change(T1-t2)/0.86

    Heat Load= C(specific heat)* M(quality output per hour )*Temp Change(T1-T2)


    3. How to maintain the chiller?

    • Check the chilled water temperature at the inlet and outlet.
    • Inspect the condenser water temperature at the inlet and outlet.
    • Monitor the compressor's power consumption and current.
    • Verify the oil level and temperature in the sump.
    • Measure the pressures of the condenser and evaporator.
    • Record and check the oil pressure.
    • Listen for any unusual noise or vibration in the system.

    4. What kind of after-sales service can we provide?

    24 hours Online support;

    Video technical support;

    Overseas third-party support available and etc.


    Buy 40 Ton Air Cooled Scroll Type Water Chiller 144KW Air Cooled Industrial System for Extrusion Machine at wholesale prices
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Anges Machinery Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0