SUS310S Vertical Muffle Furnace Electric Vacuum Nitrogen Hydrogen Atmosphere

Categories Vacuum Muffle Furnace
Model Number: HWF160-10NH
Range of Applications: Industrial
Type: Electric Holding Furnace
Usage: Ceramic Sintering
Fuel: Electric
Atmosphere: Vacuum/Nitrogen/Hydrogen
Effective Chamber Dimensions: 500*500*650mm(W*H*D)
Rated Temperature: 900°c
Maximum Temperature: 1000°c
Transport Package: Wooden Packaging
Specification: 1650*1950*2000mm(W*H*D)
Trademark: Chitherm
Origin: China
HS Code: 8514101000
Supply Ability: Customized
Customization: Available
Certification: ISO
Place Style: Vertical
Place of Origin: China
Brand Name: Chitherm
MOQ: 1
Price: Negotiable
Packaging Details: Customized
Delivery Time: Customized
Payment Terms: Customized
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

SUS310S Vertical Muffle Furnace Electric Vacuum Nitrogen Hydrogen Atmosphere

Chitherm Hwf160-10nh Vacuum Atmosphere Tank Furnace for Temperature Processing ISO Certified and 1000°c Maximum Temperature
1. Equipment Name and Model:
HWF160-10NH Vacuum Atmosphere Tank Furnace

2. Technical Indicators and Basic Configuration
2.1 Rated Temperature: 900°C;
2.2 Maximum Temperature: 1000°C;
2.3 Tank Material: SUS310S;
2.4 Tank Dimensions: Φ750×900mm (d×D);
2.5 Effective Size: 500×500×650mm (W×H×D);
2.6 Material Loading Method: Stainless steel saggars, a total of 7 layers, 2 saggars per layer, 14 saggars in total;
2.7 Cooling Method: Natural cooling;
2.8 Heating Element: FEC ceramic fiber heater;
2.9 Temperature Control Stability: ±1°C, with the function of PID parameter self-tuning;
2.10 Temperature Uniformity: ±5°C (tested in an empty furnace at a constant temperature of 900°C for 1 hour), with a reserved detection port;
2.11 Temperature Control Thermocouple: K graduation;
2.12 Number of Temperature Control Points: 3 points;
2.13 Number of Temperature Measuring Points: 1 point;
2.14 Number of Temperature Control Segments: Default 9 segments;
2.15 Sintering Atmosphere: Nitrogen, hydrogen or a mixture of nitrogen and hydrogen;
2.16 Oxygen Content Detection: Equipped with an oxygen content analyzer that can be used under reducing atmosphere conditions;
2.17 Waste Gas Treatment: The discharged hydrogen is ignited when passing through the ignition device;
2.18 Alarm and Protection: Sound and light alarm protection for over-temperature, thermocouple breakage, low air pressure, low water pressure, ignition, motor under-phase and reverse-phase, unqualified vacuum degree, etc., and it has the function of power-off protection for over-temperature alarm;
2.19 Design Power: 40kW;
2.20 Typical Heat Preservation Power of the Empty Furnace: ≤25kW;
2.21 Heating Rate: ≤5°C/min;
2.22 Surface Temperature Rise: <35°C;
2.23 Ultimate Vacuum Degree: 10Pa;
2.24 Equipment Weight: Approximately 1500Kg;
2.25 Equipment Color: Light gray;
2.26 Reference Dimensions of the Appearance: 1650×1950×2000mm (W×H×D), and the specific dimensions shall be subject to the actual product.Chitherm 1000&ordm; C Hwf160-10nh Vacuum Atmosphere Tank FurnaceChitherm 1000&ordm; C Hwf160-10nh Vacuum Atmosphere Tank Furnace
3. General Technical Description
Chitherm 1000&ordm; C Hwf160-10nh Vacuum Atmosphere Tank Furnace
Figure 1 Schematic Diagram of the Equipment Structure
3. Delivery List
Table 1 Delivery list
ItemNoteQty.
Basic ComponentsFurnace1 SET
inspection certificateCertificate of major outsourced components1 SET
Technical DocumentsInstructions, technical documents of the major outsourced parts, etc1 SET
Key ComponentsHeating ElementFEC ceramic fiber heater1 SET
Vacuum System1 SET
Touch Screen1 SET
Temperature ControllerAzbil1 SET
ThermocoupleType K1 PCS
PLC1 SET
Spare PartsSSR1 PC


4. Facility Requirements
  1. Environmental Conditions: temp.: 0~40ºC, humidity ≤ 80%RH, no corrosive gas, no strong airflow disturbance.
  2. N2 Conditions: 99.999% purity, working pressure: 0.2-0.4MPa, Max gas consumption 2-6 m3/h.
  3. H2 Conditions: working pressure: 0.2-0.4MPa, Max gas consumption 1-3m3/h.
  4. Water Conditions: clean, no corrosive water, working pressure 0.1-0.3MPa, 3-9L/min
  5. Ventilation System: non-contact access to the user pumping system, pumping capacity is greater than 15m3/h
  6. Ground Requirements: horizontal, no obvious vibration, load-bearing> 500 kg/m2;
  7. Power Condition(TBD): capacity > 55kVA, 3-phases 5-lines, voltage 220/380V, frequency 50Hz. Fire line: yellow, green, red, Zero line: blue, Ground line: yellow-green;
  8. Installation Site: 3000mm×2500mm×3000mm(D×W×H), with an installation area greater than 7.5m2.
Chitherm 1000&ordm; C Hwf160-10nh Vacuum Atmosphere Tank Furnace
Buy SUS310S Vertical Muffle Furnace Electric Vacuum Nitrogen Hydrogen Atmosphere at wholesale prices
Send your message to this supplier
 
*From:
*To: Hefei Chitherm Equipment Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0