Model Number: BF220-17NH
Range of Applications: Industrial
Type: Electric Holding Furnace
Usage: Drying
Fuel: Electric
Atmosphere: H2/N2
Effective Chamber Dimensions: Φ750*500
Warranty: 1 Year
Transport Package: Wooden Packaging
Specification: 2240*2900*3000mm(W*H*D)
Trademark: Chitherm
Origin: China
HS Code: 8514101000
Supply Ability: Customized
Customization: Available
Certification: ISO
Place Style: Vertical
Place of Origin: China
Brand Name: Chitherm
MOQ: 1
Price: Negotiable
Packaging Details: Customized
Delivery Time: Customized
Payment Terms: Customized
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Electric Melting Nitrogen Atmosphere Box Furnace Oven For Industrial

Electric Melting Furnace 1600 deg C Temperature Atmosphere Bell Furnace for Industrial Fuel Efficiency Applications
1. Equipment Name and Model:
BF220-17NH High-Temperature Atmosphere Bell Furnace

2. Application Field:
Primarily used for high-temperature co-firing processes of alumina substrates and metal pastes (HTCC) under nitrogen-hydrogen atmosphere.
Electric Furnace 1600° C High-Temperature Atmosphere Bell Furnace Melting Furnace
Electric Furnace 1600° C High-Temperature Atmosphere Bell Furnace Melting Furnace
Electric Furnace 1600° C High-Temperature Atmosphere Bell Furnace Melting Furnace

3. Technical Specifications and Basic Configuration

  • 3.1 Rated Temperature: 1600°C
  • 3.2 Maximum Temperature: 1650°C
  • 3.3 Effective Size: Φ750×500
  • 3.4 Heating Element: Molybdenum heater
  • 3.5 Process Atmosphere: Nitrogen/Hydrogen; one nitrogen line, one hydrogen line, with the option to humidify the mixed gas after nitrogen-hydrogen mixing.
  • 3.6 Hydrogen Supply Conditions: Hydrogen cannot be supplied if the oxygen content exceeds 20ppm; if the oxygen content exceeds 20ppm during hydrogen supply, the hydrogen supply is automatically cut off.
  • 3.7 Humidification Water Temperature: ≤80°C
  • 3.8 Dew Point Range: -20 to 60°C
  • 3.9 Temperature Control Stability: ±1°C, with PID auto-tuning function.
  • 3.10 Temperature Uniformity: Better than ±5°C (tested at 1600°C for 2 hours in an empty furnace).
  • 3.11 Temperature Control Thermocouple: Type B
  • 3.12 Temperature Control Points: Three independent heating zones from top to bottom, with three independent temperature control points.
  • 3.13 Temperature Control Segments: 19×19 segments
  • 3.14 Cooling Method: External water cooling, with three water cooling zones: upper, middle, and lower.
  • 3.15 Pressure Monitoring: Pressure transmitter for real-time monitoring of furnace pressure.
  • 3.16 Pressure Range: 5000~15000Pa
  • 3.17 Vacuum Detection: Vacuum gauge for detecting furnace vacuum level, with digital vacuum gauge displaying the vacuum value.
  • 3.18 Explosion Protection: Automatic opening of the exhaust valve when furnace pressure exceeds the set value.
  • 3.19 Exhaust Chimney: One exhaust port with an ignition device.
  • 3.20 Alarm Protection: Alarms for over-temperature, thermocouple break, leakage, heater break, motor overload, low water level in the humidifier, low pressure, low cooling water pressure, and UPS activation, with over-temperature alarm and power-off protection.
  • 3.21 Maximum Heating Power: 120kW
  • 3.22 Idle Furnace Insulation Power: ≤60kW
  • 3.23 Heating Rate: RT~1200ºC ≤5ºC/min, 1200~1600ºC ≤3ºC/min
  • 3.24 Surface Temperature Rise: <35ºC
  • 3.25 External Reference Dimensions: 2240×2900×3000mm (W×H×D, excluding control cabinet), subject to final product specifications.
4. Delivery List
Table 1 Delivery list
ItemNoteQty.
Basic ComponentsFurnace1 SET
Inspection CertificatesCertificates of major outsourced components1 SET
Technical DocumentsInstructions, technical documents of the major outsourced parts, etc1 SET
Key ComponentsMolybdenum wireCustom-made1 SET
Mass Flow MeterAzbil or HORIBA1 SET
ThermocoupleSong Qi1 SET
micro-oxygen analyzer
1 SET
Temperature Control ModuleAzbil3 SET
Vacuum Pump
1 SET
Dew Point Transmitter
1 SET
Touch ScreenMCGS1 SET
Spare PartsHeater
1 PC

5.Normal Operating Conditions

  • Environmental Conditions: The equipment must be installed indoors, with a temperature range of 0~40ºC, humidity ≤80%RH, no corrosive gases, and no strong airflow disturbances.
  • Water Supply Conditions: 0.1~0.3Mpa, clean and non-corrosive, with a supply flow rate of approximately 50L/min.
  • Ventilation System: Non-contact connection to the user's exhaust system, with an exhaust capacity greater than 15m³/h.
  • Floor Requirements: Level, with no significant vibrations, and a load-bearing capacity >500kg/m².
  • Power Conditions: Capacity greater than 160kVA, 3-phase 5-wire, voltage 220/380V, frequency 50Hz. Live wires: yellow, green, red; neutral wire: blue; ground wire: yellow-green.
  • Installation Site: 4500mm×3500mm×4500mm (W×H×D), with an installation area greater than 18m².
  • Equipment Grounding: The equipment must be reliably grounded.
Electric Furnace 1600&deg; C High-Temperature Atmosphere Bell Furnace Melting Furnace
Buy Electric Melting Nitrogen Atmosphere Box Furnace Oven For Industrial at wholesale prices
Send your message to this supplier
 
*From:
*To: Hefei Chitherm Equipment Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0