| Sign In | Join Free | My benadorassociates.com | 
              
  | 
      
| Categories | Gas Detector Sensor | 
|---|---|
| Brand Name: | KACISE | 
| Model Number: | CO-A4/CO-A4+ | 
| Certification: | CE | 
| Place of Origin: | CHINA | 
| MOQ: | 1PCS | 
| Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram | 
| Supply Ability: | 1000 Piece/Pieces per Week negotiable | 
| Delivery Time: | 5-8 work days | 
| Packaging Details: | each unit has individual box and all boxes are packed in standard packages or customers requests available | 
| Sensitivity: | 220 to 410 | 
| Response time: | < 30 | 
| Zero current: | -100 to +10 | 
| Noise*: | 20 | 
| Linearity: | < ± 1 | 
| Overgas limit: | 2000 | 
| Company Info. | 
| Xi'an Kacise Optronics Co.,Ltd. | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
CO-A4/CO-A4+ Carbon Monoxide Sensor
The CO-A4 sensor is a PPB sensor that is designed for industrial safety and environmental air quality applications with best-in-class baseline stability. The A series is the most widely used sensor format for portable gas detection applications. This product is available in our standard format (CO-A4) and with our patented Integrated Smart Technology (CO-A4+) that has an IST board with a memory chip and temperature sensor integrated in the sensor. The + sensors store specific calibration, specification, and identification
data on every sensor allowing plug and play operation. The on-board temperature sensor improves the accuracy and simplicity of temperature compensation algorithms.



Performance  | Sensitivity Response time Zero current Noise* Range Linearity Overgas limit  | nA/ppm in 2ppm CO t90 (s) from zero to 10ppm CO nA in zero air at 20°C ±2 standard deviations (ppb equivalent) ppm limit of performance warranty ppm CO error at full scale, linear at zero, 15ppm CO maximum ppm for stable response to gas pulse  | 220 to 410 < 30 -100 to +10 20 500 < ± 1 2000  | 
| "Tested with Alphasense AFE low noise circuit | |||
| Lifetime | Zero drift Sensitivity drift Operating life | ppb equivalent change/year in lab air % change/year in lab air, monthly test months until 50% original signal (24-month warranted  | < ±100 < 10 > 36  | 
| Environmental | Sensitivity @ -20°C Sensitivity @ 50°C Zero @ -20°C Zero @ 50°  | (% output @ -20°C/output @ 20°C) @ 5ppm CO (% output @ 50°C/output @ 20°C) @ 5ppm CO nA change from 20°C nA change from 20°C  | 50 to 85 110 to 125 10 to 40 -120 to -200  | 
| Cross Sensitivity | Filter capacity H2S sensitivity NO2 sensitivity CL2 sensitivity NO sensitivity SO2 sensitivity H2 sensitivity C2H4 sensitivity NH3 sensitivity  | ppm·hrs H2S % measured gas @ 5ppm H2S % measured gas @ 5ppm NO2 % measured gas @ 5ppm CL2 % measured gas @ 5ppm NO % measured gas @ 5ppm SO2 % measured gas @ 100ppm H2 at 20°C % measured gas @ 100ppm C2H4 % measured gas @ 20ppm NH3  | 250,000 < 0.1 < -2 < 0.1 < -2 < 0.1 < 50 < 0.5 < 0.1  | 
| Key Specifications | Temperature range Pressure range Humidity range Storage period Load resistor Weight  | °C kPa % rh continuous months @ 3 to 20°C (stored in sealed pot) Ω (AFE circuit is recommended) g  | -30 to 50 80 to 120 15 to 90 6 33 to 100 < 6  | 
                                 
                             |