| Brand Name: | ASAIR |
| Model Number: | AO-06 |
| Place of Origin: | China |
| MOQ: | 1 |
| Price: | Negotiable |
| Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
| Delivery Time: | 3-5workingdays |
| Packaging Details: | Standard Package |
| Operating principle: | Partial pressure electrochemical |
| Output voltage: | 9~13mV(in ambient air) |
| Measurement range: | 0~100% |
| Temperature compensation: | <2%0, equivalent (0~40°C) |
| Response time (T90): | <15s |
| External load resistor: | >10kQ |
| Company Info. |
| ShenzhenYijiajie Electronic Co., Ltd. |
| Verified Supplier |
| View Contact Details |
| Product List |
AO-06 Gas Sensor Detect Oxygen Concentration Medical Electrochemical Long Life And High Respond
1. Product Overview
AO-06 is an electrochemical oxygen sensor for measuring oxygen
concentration, designed for medical equipment. The interface model
of AO-06 oxygen sensor is 5520257-2. The sensor adopts a molded
design, fast response speed, long life, and can achieve domestic
substitution. This sensor provides customers with excellent quality
while reducing costs. The pin definition of AO-06 oxygen sensor and
A0-07 oxygen sensor
is different.
2. Application
No external power supply is required to use AO-06. The sensor is
calibrated before leaving the factory. To avoid temperature
influence, the sensor has temperature compensation function. AO-06
can be used as a sensing element of oxygen analyzer, such as
a control element of hydrogen generator, medical ventilator,
anesthesia equipment, and thermostat. 3. Product Features ·Linear
output ·No external power supply required, ·Temperature
compensation ·Accurate and reliable ·Fast response speed
·Anti-interference
Using A0-06 requires no external power supply. Sensors have been
calibrated before leaving the factory. To avoid the influence of
tempera-
ture, temperature compensation function is applied in sensors.
A0-06 can be used as the sensing component in oxygen analyzer, such
as con-
trol component in oxygen generator, medical ventilator, anesthesia
equipment, incubator.
| Connector | P/N 5520257-2 |
| Housing material | White ABS |
| Weight | 40g(nominal) |
| Operating temperature range | 0~50°C |
| Operating pressure range | 0.5~2.0bar |
| Operating humidity range | 0~99%RH(non-condensing) |
| Long-term output drift in 100% 02 | <5%(voltage loss/year) |
| Expected operating life | 1.5 x 10³ % O, hours (20°C) 0.8 x 10s % O, hours (40°c) |
| Warranty | 13 months from date of dispatch |


|