| Model | JTR-1200 | JTR-1200D | JTR-1200L |
| Detailed description |
| External dimensions | 7050 x 1430 x 1530mm | 7050 x 1660 x 1530mm | 7050 x 1660 x 1530mm |
| Main color | White ripples | White ripples | White ripples |
| NET weight | Approx. 3000KG | Approx. 3350KG | Approx.3300KG |
| Exhaust air volume | 10m3/min×2 Access Road | 10m3/min×2 Access Road | 10m3/min×2 Access Road |
| Power supply | 5 cable 3-phase; 380V 50/60HZ; (□ O: 220V 50/60HZ) | 5 cable 3-phase; 380V 50/60HZ; (□ O: 220V 50/60HZ) | 5 cable 3-phase; 380V 50/60HZ; (□ O: 220V 50/60HZ) |
| Power | Starting Power 40KW, working power 11KW | Starting Power 40KW, working power 11KW | Starting Power 40/42KW, working power 11/12KW |
| Heating time | About 25mins | About 30mins | About 30mins |
| Temperature range | Room temperature-300 °C | Room temperature-300 °C | Room temperature-300 °C |
| Maximum width of PCB | 400mm (optional 460mm) | 250 mm × 2(50-270 mm for dual channels and 50-490 mm for single
channel) | 610mm |
| Height of parts | 30 mm above board/25 mm below board | 30 mm above board/25 mm below board | Top 25 mm/bottom 25 mm |
| Direction of transportation | Left to right (□ o: Right to left) | Left to right (□ o: Right to left) | Left to right (□ o: Right to left) |
| Fixing mode of guide rail | Anterior fixation (□ O: posterior fixation) | Double track 1,3 fixed (□ o: 1,4 fixed) | Anterior fixation (□ O: posterior fixation) |
| Height of guide rail from ground | 900±20 mm | 900±20 mm | 900±20 mm |
| Speed of transportation | 300-2000mm/min | 300-2000mm/min | 300-2000mm/min |
| Parameter storage | The parameters and status of various production settings can be
stored | The parameters and status of various production settings can be
stored | The parameters and status of various production settings can be
stored |
| Abnormal alarm | Ultra-high or ultra-low temperature alarm, sound, light two ways | Ultra-high or ultra-low temperature alarm, sound, light two ways | Ultra-high or ultra-low temperature alarm, sound, light two ways |
| Filling of lubricating oil | Automatic manual mode can be freely switched | Automatic manual mode can be freely switched | Automatic manual mode can be freely switched |
| Device configuration |
| Number of heating/cooling zones | Top 12, bottom 12 heating zone, top 3/Bottom 3 cooling zone | Top 12, bottom 12 heating zone, top 3/Bottom 3 cooling zone | Top 12, bottom 12 heating zone, top 3/Bottom 3 cooling zone |
| Control system | Win10 + Business + PLC | Win10 + Business + PLC | Win10 + Business + PLC |
| Temperature control mode | PID closed-loop control + SSR driver | PID closed-loop control + SSR driver | PID closed-loop control + SSR driver |
| Temperature test line | Article 4 | Article 4 | Article 4 |
| Transportation system | Single Rail + Mesh Belt Transportation | Double Guide Rail + Mesh Belt Transportation | Single Rail + Mesh Belt Transportation |
| Mode of transport control | Frequency converter + imported transport motor | Frequency converter + imported transport motor | Frequency converter + imported transport motor |
| Chain structure | Double Row chain buckle anti-jamming plate type | Double Row chain buckle anti-jamming plate type | Double Row chain buckle anti-jamming plate type |
| Structure of guide rail | Integral and sectional type | Integral and sectional type | Integral and sectional type |
| Width adjustment of guide rail | Width adjustment of guide rail by electric motor | Width adjustment of guide rail by electric motor | Width adjustment of guide rail by electric motor |
| Start the top cover | The upper cover is electrically opened for convenient cleaning in
the furnace | The upper cover is electrically opened for convenient cleaning in
the furnace | The upper cover is electrically opened for convenient cleaning in
the furnace |
| UPS | Backup power supply | Backup power supply | Backup power supply |
| Cooling method | Forced Air Cooling | Forced Air Cooling | Forced Air Cooling |