| Low-Frequency Signal Contacts - Current Rating (Standard Signal
Contact) | One contact loaded, 25C: 3.3A max; One contact loaded, 85C: 2.6A
max; All contacts loaded, 25C: 3.0A max; All contacts loaded, 85C:
2.2A max |
| Low-Frequency Signal Contacts - Current Rating (T-Contact) | One contact loaded, 25C: 8.5A max; One contact loaded, 85C: 6.5A
max; All contacts loaded, 25C: 3.5A max; All contacts loaded, 85C:
2.6A max |
| Low-Frequency Signal Contacts - Current Rating (Flex Circuit
Assembly) | Per individual track, 25C: 1.0A max |
| Low-Frequency Signal Contacts - Working Voltage | Pre-Cabled & Cable Assemblies: 300V DC or AC peak; Others: 800V DC
or AC peak |
| Low-Frequency Signal Contacts - Voltage Proof | 1,200V DC or AC peak |
| Low-Frequency Signal Contacts - Contact Resistance | Initial: 20m max; After Conditioning: 25m max |
| Low-Frequency Signal Contacts - Insulation Resistance | Initial: 1,000M min; Hot After Conditioning: 100M min |
| Low-Frequency Signal Contacts - Creepage Path | 0.35mm min |
| Low-Frequency Signal Contacts - Air Gap | 0.35mm min |
| Low-Frequency Signal Contacts - Environmental Classification | 55/125/56 |
| Low-Frequency Signal Contacts - Operating Temperature Range | -55C to +125C |
| Low-Frequency Signal Contacts - Low Air Pressure Severity | 300 mbar (9,144m/30,000ft) up to 360V DC |
| Low-Frequency Signal Contacts - Salt Spray (L-Tek) | BS2011 Part 2.1Kb Severity 2 |
| Low-Frequency Signal Contacts - Salt Spray (J-Tek & Mix-Tek) | EIA364 Test Procedure 26 condition A |
| Low-Frequency Signal Contacts - Vibration Severity (Standard Signal
Contact) | 10Hz to 2,000Hz, 0.75mm, 98m/s (10G), 6 hours; 10Hz to 81.73Hz,
1.5mm peak-to-peak; 57.55Hz to 2,000Hz, 196.2m/s (20G), 2 hours |
| Low-Frequency Signal Contacts - Shock Severity (Standard Signal
Contact) | 981m/s (100G), 18 shocks |
| Low-Frequency Signal Contacts - Bump Severity (Standard Signal
Contact) | 390m/s (40G), 4,00010 bumps |
| Low-Frequency Signal Contacts - Vibration Severity (T-Contact) | 10Hz to 13.6Hz, 35mm peak-to-peak; 13.6Hz to 41.6Hz, 1.5mm
peak-to-peak; 41.6Hz to 2,000Hz, 392.4m/s (40G), 6 hours |
| Low-Frequency Signal Contacts - Shock Severity (T-Contact) | 981m/s (100G) |
| Low-Frequency Signal Contacts - Clip Retention in Body | 18N min (10N min from sample of 10, avg 22N) |
| Low-Frequency Signal Contacts - High Temp Long Term | 1,000 hours at 85C |
| Low-Frequency Signal Contacts - High Temp Short Term | 250 hours at 125C |
| Low-Frequency Signal Contacts - Contact Retention in Housing | 10N min |
| Low-Frequency Signal Contacts - Contact Replacement in Housing
(Male Crimp Jackscrew) | 2 operations at 10N |
| Low-Frequency Signal Contacts - Durability (Standard Signal
Contact) | 500 operations |
| Low-Frequency Signal Contacts - Durability (T-Contact) | 1,000 operations |
| Low-Frequency Signal Contacts - Contact holding force (Standard
Signal Contact) | 0.2N min |
| Low-Frequency Signal Contacts - Insertion Force (per contact) | M80 Standard Signal: 2.0N max; M83 Signal: 1.0N max; T-Contact:
4.0N max |
| Low-Frequency Signal Contacts - Withdrawal Force (per contact) | M80 Standard Signal: 0.2N min; M83 Signal: 0.2N min; T-Contact:
0.5N min |
| Low-Frequency Signal Contacts - Cable Contact Replacement in
Housing | up to 2 times max |
| Low-Frequency Signal Contacts - Contact Wipe (T-Contact) | 2.00mm min |
| Low-Frequency Signal Contacts - Wire Termination Range | See Component Specification C049XX (latest issue) |
| Coax Contacts - Impedance | 50 |
| Coax Contacts - Frequency Range | 6GHz (dependent on cable type/board layout) |
| Coax Contacts - VSWR | M80-310: 1.19 + (0.04 x Freq) GHz max; Others: 1.05 + (0.04 x Freq)
GHz max |
| Coax Contacts - Voltage Rating | 180V AC at 500mA |
| Coax Contacts - Voltage Proof | (data incomplete) |