| Brand Name: | CESTSEN |
| Model Number: | OZONE-300 LN |
| Place of Origin: | Shenzhen |
| MOQ: | 1PCS |
| Payment Terms: | T/T |
| Supply Ability: | 300 pieces+One month |
| Delivery Time: | 7-15 Working day |
| Measuring range: | 0-300g / Nm3Built-in customizable |
| Display resolution: | 0.01 g/m3,0.01ppm; |
| Gas flow rate: | 0.5L±0.2L/min; |
| Input pressure: | <0.1MPa; |
| Concentration error: | maximum 0.3%FS; |
| Linear error:: | maximum 0.2%FS; |
| Company Info. |
| Shenzhen Wanyi Technology Co., LTD |
| Verified Supplier |
| View Contact Details |
| Product List |
Wall-mounted Ozone Concentration Analyzer-The Ultraviolet Method Can Be Used For Continuous Measurement
1. Product profile
OZONE-300 LN series fixed ozone analyzer is designed and
manufactured according to the verification and calibration method
of the national environmental standard of the People's Republic of
China-ultraviolet photometry method, and "ozone and ozone Generator
for Water Treatment" of the Ministry of Construction of the
People's Republic of China. The current ozone concentration is
calculated by measuring the change of optical signal intensity
before and after the absorption of ultraviolet light. Equipment
using advanced double light road ultraviolet light source system,
equipped with lamp intelligent management system, after boot can
make the ultraviolet lamp quickly to measurement status, using
foreign separation light pool technology, equipment has no leakage,
high pressure resistance, large flow sampling gas impact, easy to
clean, easy maintenance, simple operation, low use cost, etc. It is
mainly used for continuous detection of ozone gas in various
industrial environments, and can also be used for detection of
ozone gas in pipelines, containers and other environments in
operation. Widely used in pharmaceutical, chemical, municipal,
sewage treatment and other industries, the ozone generator export
concentration and ozone generator output measurement.
The ozone analyzer has a touch screen operation interface to
display the concentration of ozone gas in real time, with pressure
and temperature compensation and display, and can set the automatic
zero calibration time and manual zero calibration mode.high
concentration (g/Nm3) Range is equipped with flow input function,
which can display the output of ozone generator in real time. With
two sets of relay signal output, the user can freely choose the
high alarm point and low alarm point signal output connection. The
core component adopts ultraviolet long life light source system and
high light transmittance quartz sheet to ensure the stability of
zero point and prevent zero point drift from affecting the accuracy
of detection concentration. According to the independent optical
tank structure of pressure resistant and impact resistant designed
by foreign optical tank technology, the gas flow, pressure and flow
rate remain unchanged during the zero operation, so as to prevent
the impact of the air zero. The zero operation can be completed
without closing the ozone intake, ensuring that the equipment can
run continuously for 24 hours a day.
Application fields: ozone generator manufacturers, municipal water
industry, industrial sewage industry, fine chemical industry food
and drinking water industry, space disinfection industry, swimming
pool disinfection industry, essence synthesis industry and other
ozone generator industry.

2. Product characteristics
Test method: dual-light path ultraviolet light absorption method,
long-life light source system, high measurement accuracy.
Measurement principle: according to the Lambert-Beer law, accurate
measurement through the luminosity absorption principle.
Light source system: foreign long-life ultraviolet light source
system (wavelength 253.7nm), free warranty for 3 years.
Usage mode: indoor installation and use, equipped with power supply
and signal terminals.
Optical pool system: separated optical pool technology, no leakage,
high pressure resistance, large flow rate sampling gas impact.
Intelligent compensation: built-in temperature and pressure
compensation and display, with light source automatic compensation
function.
Operation mode: the user can select the manual zero calibration and
automatic zero calibration according to the running status, and the
automatic zero calibration time can be set.
Display units: g / Nm 3, mg / NL,% WT, ppm, mg / Nm 3 are optional.
Data display: high-definition color touch screen, high
concentration range set into the gas mass flow rate, real-time
display of output.
Output function: 4-20 mA, RS485 communication, two groups of alarm
point output, electronic flowmeter input, etc.
Standard configuration: anti-corrosion flowmeter, ozone exhaust
destroyer, air intake filter.
OZONE-300 LN series stationary ozone analyzer, optional range and working mode.
range | Sampling method | application area |
0-300g/Nm3 | Positive pressure sampling, with pressure, and temperature compensation | Real-time detection of ozone generator outlet concentration. |
0-100g/Nm3 | Positive pressure sampling, with pressure, and temperature compensation | Real-time detection of ozone generator outlet concentration. |
0-50g/Nm3 | Sampling at positive or negative pressure, with pressure, and temperature compensation | Ozone generator outlet or exhaust gas ozone concentration detection. |
0-1000ppm | Sampling at positive or negative pressure, with pressure, and temperature compensation | Real-time detection of ozone concentration in the box. |
3.Qualification
Model: OZONE-300 LN series
Measuring range: 0-300g / Nm3Built-in customizable
Optional range: 0-200g / Nm3,0-100g/Nm3,0-50g/Nm3,0-1000ppm,
Light source life: about 30,000-50,000 hours;
Sampling method: positive pressure sampling, negative pressure sampling (optional);
Display interface: 4.3-inch touch screen operation interface;
Content interface: ozone concentration, temperature, and pressure;
Auxiliary functions: temperature compensation, pressure compensation;
Display unit: g / Nm3,mg/NL,%WT,ppm ,mg/Nm3selectable;
Display resolution: 0.01 g/m3,0.01ppm;
Gas flow rate: 0.5L±0.2L/min;
Input pressure: <0.1MPa;
Concentration error: maximum 0.3%FS;
Linear error: maximum 0.2%FS;
Zero-point drift: <± 0.3%.FS;
Reaction time: 0.03 seconds, 0.3 seconds;
Ambient temperature: -20~50℃;
Line interface mode: quick twist (stainless steel);
Tandem sample diameter: Φ 8 (8mm * 6mm) (optional);
Bypass sampling diameter: Φ 6 (6mm * 4mm);
Communication mode: RS-485;
Output mode: 4-20 mA (active);
Telecom signal: high alarm point following electrical signal, low alarm point following electrical signal;
Power supply: AC 110-220V;
Dimensions: 230mm (height) 330mm (W) 150mm (deep);
Note: 1 mg/L = 1 g/m3 = 467 PPM;
Free warranty: 24 months (host);
Note: Standard configuration (built-in): flowmeter, ozone tail gas catalyst, air intake filter.
OZONE-300 LN series fixed ozone analyzer-positive pressure sampling connection process

|