Rexroth High Pressure Hydraulic Gear Pump for Steel Mill and Industrial Metallurgy Applications with Quantitative Flow

Categories Gear Pump
Brand Name: Rexroth
Model Number: PGH4-2X/063RE07VE4 PGH4-2X/063RR07VU2 PGH4-2X/063LE07VU2 PGH4-2X/063LR07VU2 PGH4-2X/080RE07VU2
Certification: ISO
Place of Origin: German
MOQ: 1
Price: 2
Payment Terms: MoneyGram,Western Union,T/T,D/P,D/A,L/C
Supply Ability: 100
Delivery Time: 2 weeks
Packaging Details: wooden box
whatsapp: +85267220981
Email: Yli97584@gmail.com
Shaft Diameter: 25 mm
Origin: Germany
Theory: Rotary Pump
Seal Type: Lip seal
Warranty: Free Warranty
Pressure: High Pressure
Shaft Type: Keyed
Power: Electric
Rotation: 0.2-cp can be transported in reverse
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Rexroth High Pressure Hydraulic Gear Pump for Steel Mill and Industrial Metallurgy Applications with Quantitative Flow

PGH4-2X/063RE07VE4
PGH4-2X/063RR07VU2
PGH4-2X/063LE07VU2
PGH4-2X/063LR07VU2
PGH4-2X/080RE07VU2 Steel mill industrial metallurgy German Rexroth hydraulic pump quantitative high-pressure gear pump

whatsapp+85267220981emailyli97584@gmail.com
Brand NameRexrothPlace of Origin
Germany
Warranty12 MonthsVideo outgoing-inspectionProvided
Machinery Test ReportProvidedApplicationMachinery Repair Shops
MaterialIronConditionOringal
TypePGH4-2X/063RE07VE4
PGH4-2X/063RR07VU2
PGH4-2X/063LE07VU2
PGH4-2X/063LR07VU2
PGH4-2X/080RE07VU2
Quality100% Tested Great Performance
CertificationISOFeatureLong Life Low Noise
FunctionFilter Diesel OilPowerHydraulic Power
Payment TermT/T 100%

PGH5-2X/160RE07VU2PGH4-2X/050RE11VE4PGH3-1X/016RF07MK0
PGH5-2X/125RR11VU2PGH4-2X/040RE11VU2PGH3-1X/016RE07ME4
PGH5-2X/125RE11VU2PGH4-2X/032RR11VU2PGH3-1X/016LE07MU2
PGH5-2X/125RE11VE4PGH4-2X/032RE11VU2PGH3-1X/010RE07MU2
PGH5-2X/100RE11VE4PGH4-2X/032RE11VE4PGH2-X/008LR07VU2
PGH5-2X/100LF11VK0PGH4-2X/025RE11VU2PGH2-X/008LE07VU2
PGH5-2X/080RR18VU2PGH4-2X/025RE11VU2PGH2-X/006RE07VU2
PGH5-2X/080RE11VE4PGH4-2X/025RE11VE4PGH2-X/005RR07VU2
PGH5-2X/063RR11VU2PGH4-2X/020RE11WU2PGH2-2X/008RR07WU2
PGH5-2X/063RE11VU2PGH4-2X/020RE11VU2PGH2-2X/008RE07WU2
PGH5-2X/063RE11VE4PGH4-2X/020LR18VU2PGH2-2X/008RE07VU2
PGH5-21/160RE07VU2PGH4-21/050RE11VE4PGH2-2X/008LR07VU2
PGH5-21/125RE11VE4PGH4-21/040RE11VU2PGH2-2X/008LE07VU2
PGH5-21/080RE11VU2PGH4-21/032RE11VE4PGH2-2X/006RE07VU2
PGH4-3X/050RE11VU2PGH4-21/025RE11VU2PGH2-2X/005RR07VU2
PGH4-3X/020RR11VU2PGH3-2X/016RE07VU2PGH2-2X/005RE07VU2
PGH4-2X/100RE07VU2PGH3-2X/013RR07VU2PGH2-1X/006RE07MU2
PGH4-2X/080RF07VK0PGH3-2X/013RE07VU2PGH2-1X/006RE07ME4
PGH4-2X/080LF47VK0PGH3-2X/011RE07VU2PGH2-1X/005RE07MU2
PGH4-2X/063RE07VE4PGH3-2X/011LR07VU2PGH2-1X/005LE07MU2
PGH4-2X/050RE11VU2PGH3-2X/011LE07VU2

FAQ:

What precautions should be taken during the installation of PGH Series Gear Pumps?

• Ensure the pump’s rotational direction matches the system’s requirements (reverse rotation can cause internal component damage).

• Keep the suction line length within 1 meter and avoid sharp bends to prevent insufficient oil suction.

• Tighten the flange bolts to the torque specified in the manual (typically 18-22 N·m for standard models) to avoid oil leakage or housing deformation.

3. How to resolve abnormal noise from a PGH Series Gear Pump during operation?

First, check if the hydraulic oil level is too low (topping up to the standard level if needed); second, inspect for air bubbles in the oil circuit (bleeding the system to remove air); finally, check if the bearing is worn (replacing the bearing if there is excessive radial play).

4. How often should maintenance be performed on PGH Rexroth Gear Pumps?

For general industrial applications, routine inspection (checking oil level, temperature, and leakage) should be conducted monthly; oil change and filter replacement are recommended every 6 months or after 2000 hours of operation; a comprehensive disassembly and inspection of the pump should be carried out every 2-3 years.

5. Can PGH Rexroth Gear Pumps be used in high-temperature environments for a long time?

No. The maximum allowable long-term operating temperature of PGH Rexroth Gear Pumps is 80°C. Prolonged use in environments exceeding this temperature will accelerate the aging of internal seals and bearings, significantly reducing the pump's service life and even causing sudden failures.