| Brand Name: | LONROY |
| Place of Origin: | Guangdong, China |
| MOQ: | 1 |
| Power: | 1.8KW |
| Voltage: | 220 V |
| Protection Class: | Ip56 |
| Test chamber temperature: | 50℃ ± 3℃ |
| Test light source: | UV lamp MLU type 300W |
| Time setting range: | 0 - 300h |
| Cooling plate material: | Copper |
| Light output power: | > 40W / m² |
| Sample distance: | 300mm |
| Inlet water temperature: | 16℃ ± 2℃ |
| Outlet water temperature: | 16℃ ± 2℃ |
| Working temperature: | Not lower than 20℃ |
| Equipment composition: | UV irradiation detector and constant temperature circulating water device |
| Water supply requirement: | Not required |
| Power supply: | AC: 220V / 1.8KW |
| Company Info. |
| DONGGUAN LONROY EQUIPMENT CO LTD |
| Verified Supplier |
| View Contact Details |
| Product List |
Ultraviolet Irradiation Detector Insulated Glass UV Radiation Tester Glass Ultraviolet Radiation Resistance Testing Machine
Product Introduction
The ultraviolet irradiation detector is designed and manufactured in accordance with the technical requirements of the national standard GB/T11944-2012 "Insulated Glass". It is a testing equipment used to examine the ultraviolet radiation resistance of insulating glass.
Working principle
Ultraviolet lamps are installed in a sealed test chamber. The glass sample is placed in an appropriate position within the chamber and exposed to ultraviolet radiation. A cooling plate is placed closely against the other side of the sample, and the cooling plate is cooled by tap water. During the test, it is checked whether fog, oil or other contaminants appear on the cooling plate after the insulating glass is exposed to ultraviolet radiation, in order to determine the insulating glass's resistance to ultraviolet radiation.
Ultraviolet Irradiation Detector Insulated Glass UV Radiation Tester Glass Ultraviolet Radiation Resistance Testing Machine
Technical Specification
Temperature inside the test chamber | 50℃ ± 3℃ |
Power supply / power | AC: 220V / 1.8KW |
Cooling plate material | Copper |
Light output power | > 40W / m² |
Distance between sample center and light source | 300mm |
Test light source | UV lamp MLU type 300W |
Inlet and outlet water temperature of the cooling plate | 16℃ ± 2℃ |
Time setting range | 0 - 300h |
Working environment temperature | Not lower than 20℃ |
Equipment composition | Consists of a UV irradiation detector and a constant temperature circulating water device |
Note | This equipment does not require an inlet and outlet water supply |
|