Sign In | Join Free | My benadorassociates.com
benadorassociates.com
Products
Search by Category
Home > General Industrial Equipment >

15/35kV AAC AAAC ACSR Aerial Bundled Cable for Overhead Power Lines

Categories Aerial Bundled Cable ABC
Brand Name: Zhongdong
Model Number: ABC
Certification: CCC,ISO,TUV,CE
Place of Origin: Hebei,China
MOQ: Negotiable
Price: Negotiable
Payment Terms: ,L/C,T/T
Supply Ability: 100KM/Week
Delivery Time: 7-30 days based on different qty
Packaging Details: Wooden Drum/ Steel Drum
Application: overhead distribution line
Cores Nos: 1,2,3,4 more multicore
Rated Voltage: 15/35kV
Installation Degree: -20℃-90℃
Neutral Messengers: AAC, AAAC or ACSR
Insulation: PE/PVC
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

15/35kV AAC AAAC ACSR Aerial Bundled Cable for Overhead Power Lines

AAC AAAC ACSR Self Supporting Aerial Bundled Cable ABC Cable for Overhead Power Line



APPLICATION

  • AAC (All Aluminum Conductor)‌ and ‌AAAC (All Aluminum Alloy Conductor)‌ are widely used in ‌medium-voltage distribution networks‌ (e.g., rural electrification, urban overhead lines) due to their ‌lightweight and corrosion resistance‌‌.
  • ACSR (Aluminum Conductor Steel Reinforced)‌ is ideal for ‌high-voltage transmission lines‌ (e.g., 11kV-33kV) and long-distance power delivery, thanks to its ‌steel core for enhanced mechanical strength‌‌.


CONSTRUCTION

  • AAC/AAAC‌: Solid or stranded ‌aluminum/aluminum alloy conductors‌ (e.g., 95mm²×3 + 70mm²×1 for neutral line)‌
  • ACSR‌: ‌Aluminum strands wrapped around a steel core‌ (e.g., 7/2.8mm steel core with 26/2.8mm aluminum layers)‌
  • ABC Cable‌: ‌Three insulated phase conductors + one neutral conductor‌, compactly bundled with a ‌weather-resistant outer sheath‌‌



KEY FEATURES

  • Lightweight & Corrosion-Resistant‌: AAC/AAAC conductors reduce weight by 30-50% compared to copper, with superior durability in harsh environments‌
  • High Tensile Strength‌: ACSR’s steel core enables ‌long-span installations‌ (e.g., crossing rivers or mountains)‌
  • Self-Supporting Design‌: ABC cables integrate ‌insulated conductors‌ in a bundled structure, simplifying installation and reducing costs‌
  • Temperature Resistance‌: XLPE insulation allows operation in ‌-40°C to 90°C‌ ranges, suitable for extreme climates‌

SPECIFICATION


Section nominalNominal insulation thicknessMaximum wiring passagespark voltage Alternating currentspark voltage DC
mm2mmmmKVKV
101.143891016.5
161.144531016.5
251.1453012.521
351.146011524
501.527421524
701.528431524
951.529501524
1202.0311091524
1502.0312101524
1852.0313151524
2402.03146417.530

OUR PLANTS


Standard 10 sqmm 16sqmm Low Voltage Cable NYY-J NYY-O Power Cables 1

PROJECTS

Standard 10 sqmm 16sqmm Low Voltage Cable NYY-J NYY-O Power Cables 2


WHY US?


N2XS(F)2Y N2XSY Four Core MV Power Cable With Copper Conductor PVC Insulated 3


FAQ

1. What are the primary applications of AAC conductors?
AAC cables are ideal for medium-voltage urban/rural distribution due to their lightweight and corrosion resistance, commonly used in street lighting and temporary power grids.
2. How does AAAC differ from AAC in performance?
AAAC (Aluminum Alloy Conductor) offers higher tensile strength (30% improvement) and better thermal stability compared to pure aluminum AAC, making it suitable for coastal or industrial areas.
3. Why is ACSR preferred for high-voltage transmission?
ACSR's steel core reinforcement provides mechanical strength for long spans (e.g., river crossings) and reduces sag, critical for 11kV-33kV overhead lines.
4. What makes Self-Supporting Aerial Bundle Cables cost-effective?
These cables eliminate support wires by integrating insulated conductors in a bundled structure, cutting installation costs by 20-30%.
5. What temperature range can AAC/AAAC conductors withstand?
Standard AAC/AAAC operates at -40°C to 70°C, while XLPE-insulated variants (e.g., ABC) support -40°C to 90°C.
6. How is ACSR's steel core protected from corrosion?
The steel core is galvanized and often coated with moisture-proof varnish at connection points to prevent rust.
7. Which cable type is best for rural electrification projects?
Self-Supporting ABC (e.g., 3×70+1×50mm²) is recommended for three-phase four-wire systems due to its easy installation and low maintenance.
8. What are the mechanical stress limits for aerial conductors?
Under ice loading, stress must not exceed 60% of short-time breaking strength, with sag adjustments allowed within 10-15% of design stress.
9. Can AAC/AAAC be used in heavy industrial zones?
Yes, but AAAC is preferred for its enhanced chemical resistance to pollutants in industrial areas.
10. What standards govern ACSR conductor connections?
Connecting tubes must align perfectly to avoid unbalanced forces, followed by anti-corrosion coating application.









Buy 15/35kV AAC AAAC ACSR Aerial Bundled Cable for Overhead Power Lines at wholesale prices
Send your message to this supplier
 
*From:
*To: Zhongdong Cable Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0