| Brand Name: | GENY |
| Model Number: | YC1893D |
| Certification: | ISO, CE |
| Place of Origin: | CHINA |
| MOQ: | 1 PCS |
| Price: | negotiation |
| Payment Terms: | L/C,T/T,D/P |
| Supply Ability: | 30 pcs per month |
| Delivery Time: | 30 days after order confirmed |
| Packaging Details: | plywood case |
| Power of the voltage output: | 3×1500VA |
| Harmonics: | nd – 41st free programmable |
| Frequency Range: | 45 Hz – 65 Hz |
| Usage: | Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter |
| Electric Equipment: | Three-phase Three-wire |
| Theory: | Electronic Meter |
| Company Info. |
| Guangzhou GENY Electric Co., Ltd |
| Verified Supplier |
| View Contact Details |
| Product List |
GENY Electric is a leading high-tech company specializing in electric meter testing equipment and smart electrical systems. With independent core technologies, internationally certified product standards, and a strong industry reputation, GENY offers reliable, innovative solutions for global energy and automation markets.
Supports automatic, semi-automatic, and manual testing of mechanical, electronic mechanical, and electronic meters.
Constructed with aluminum alloy for a lightweight, strong, and corrosion-resistant build—perfect for long-term industrial use.
Automatic positioning of rotor marks on mechanical meter discs significantly improves testing efficiency.
Synchronized scanning head movement streamlines control and simplifies operation.
The system automatically performs a comprehensive range of meter tests:
Accuracy testing in all four quadrants: active, reactive, and apparent energy
Error repeatability test
Creep test (No-load)
Starting current test
Dial/Register test
Meter constant verification
Influence quantity tests (voltage variation, unbalance, frequency, harmonics, reverse phase sequence)
Reference standard meter calibration (lower accuracy class)
Pre-warming cycle
Dips and interruptions simulation
Tamper condition test for single-phase meters
Sub and odd harmonics tests as per IEC standards
Capable of measuring different meter constants synchronously, ensuring high accuracy and productivity.
Equipped with overload, short-circuit, and open current circuit protection, ensuring safety during operation.

|