| Sign In | Join Free | My benadorassociates.com |
|
| Categories | Stationary Meter Test Bench |
|---|---|
| Brand Name: | GENY |
| Model Number: | YC1891G |
| Certification: | ISO, CE |
| Place of Origin: | CHINA |
| MOQ: | 1 PCS |
| Price: | Negotiation |
| Payment Terms: | L/C,T/T,D/P |
| Supply Ability: | 100/Year |
| Delivery Time: | 30 Pcs Per month |
| Packaging Details: | Plywood case |
| Number of meter positions: | 3-60 (customer option) |
| Photoelectric scanning head: | option |
| Continuous current: | 100 A |
| Head adjustment:: | Individual height & depth, common flip-over frame |
| Error display Type: | LED window (one per meter position) |
| Rack material: | aluminium alloy |
| Company Info. |
| Guangzhou GENY Electric Co., Ltd |
| Verified Supplier |
| View Contact Details |
| Product List |
The YC-1891G Series Single-Phase Semi-Automatic Meter Test System is designed and manufactured in strict accordance with relevant national and industry standards, including GB/T 11150-2001 Electric Energy Meter Test Equipment, JJG 597-2005 Verification Regulation for AC Electric Energy Meter Test Systems, JG 307-2006 Verification Regulation for AC Electric Energy Meters, DL/T 614-2007 Verification Regulation for Multifunction Energy Meters, and DL/T 645-2007 Communication Protocol for Multifunction Energy Meters.
This single-phase meter test system is widely used for the verification and calibration of Class 0.2 and lower accuracy electronic single-phase energy meters, including single-phase carrier meters, prepaid energy meters, and smart energy meters. It is an ideal solution for meter testing laboratories, power utilities, and metering equipment manufacturers, offering high accuracy, reliable performance, and efficient semi-automatic operation.
Operating environment | |
Power supply | AC220 V ±10 %, 50 Hz ±2 Hz |
Ambient temperature | –10 °C … +40 °C |
Relative humidity | 35 % … 95 % |
Output Voltage | |
Voltage range | 24 V … 288 V |
Max. output power | 10 800 VA |
Voltage setting resolution | 0.01 % |
Voltage stability | 0.02 % / 50 ppm / 120 s |
Load regulation | 0.01 % |
Voltage distortion | ≤ 0.3 % (entire linear load range) |
Output Current | |
Current range | 1 mA … 120 A (on request up to 230A) |
Max. output power | 12 000 VA(MAX) |
Current setting resolution | 0.01 % |
Current stability | 0.02 % / 50 ppm / 120 sh |
Continuous current | 100 A |
Load regulation | 0.01 % |
20-min maximum current | 120 A |
Current distortion | ≤ 0.3 % (entire linear load range) |
Output Phase | |
Phase shift range | 0° … 360° |
Phase resolution | 0.01° |
Output Frequency | |
Frequency range | 45 Hz … 65 Hz |
Frequency resolution | 0.01 Hz |

|