HDT VICAT Tester with Automatic Needle for Testing Heat Distortion and Vicat Softening Point of Plastics Rubber and Nylon

Categories HDT VICAT Tester
Brand Name: TH
Model Number: XRW-300D
Certification: ISO9001
Place of Origin: BEIJING, CHINA
MOQ: 1 set
Payment Terms: T/T,L/C,D/A,D/P,Western Union,MoneyGram
Supply Ability: 15 sets per month
Delivery Time: 10~15 work days
Packaging Details: Standard export wooden cases
Product name: HDT VICAT Tester with Automatic Needle for Testing Heat Distortion and Vicat Softening Point of Plastics Rubber and Nylon
Controll: By PLC
Test station moving method: Automatic
Mainframe type: Desk type
Vicat load: 10N ± 0.2 N , 50N ± 1N
Max. deformation deviation: 0.001mm
Deformation Measuring Rage: 0 ~ 2.5mm
Sample Frame Number: 3-6 stations can be selected
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

HDT VICAT Tester with Automatic Needle for Testing Heat Distortion and Vicat Softening Point of Plastics Rubber and Nylon

HDT VICAT Tester with Automatic Needle for Testing Heat Distortion and Vicat Softening Point of Plastics Rubber and Nylon



Overview:

The Vicat Softening Point Heat Distortion Testing Machine (also referred to as the Automatic Needle Vicats Apparatus) is primarily engineered for thermal performance characterization of non-metallic materials, including plastics, rubber, and nylon. A key functional feature of the device is its ability to enable automatic elevation and lowering of the test frame at the start and conclusion of test procedures, streamlining specimen loading/unloading and test workflow efficiency.

This specialized testing instrument is dedicated to the precise determination of two critical thermal performance metrics for materials:

  1. The heat distortion temperature of non-metallic specimens
  2. The Vicat softening point temperature of electrical insulating materials

Its testing protocols align with industry standards for thermal property evaluation, providing reliable, repeatable data for material quality validation, R&D validation, and compliance assessment in related manufacturing and research fields.


Meet Standards:

GB/T 1633, GB/T 1634, ISO75, ISO306, ASTM D648, ASTM D1525, ISO 2507



Technical paremeter:

ModelXRW-300D
Technical data

1.Equipped with 6 stations (Ability to test 6 samples simultaneously)

2.Automatic performance: A left for moving the samples

3.Air above 150 Degree centigrade, 150 Degree centigrade the following water

or natural cooling.

4.Deformation measurement: High precision digital display dial gauge

5.Heating Rate: 50oC/h, 120oC/h

6.Max. Temperature Deviation: ±0.5oC

7. Deformation deviation: 0.01mm

8.Vicat load: 10N ± 0.2 N , 50N ± 1N

9.Fiber stress: 0.455 Mpa and 1.82 Mpa

10.temperature-control Range: room temperature ~ 300oC

11.Deformation Measuring Rage: 0 ~ 10mm

12.Sample Frame Number: 3~6

13.Test Span: 60~120mm

14.Heating Power: 6KW

15.Power Supply: 220V 50Hz

16.Display: Color touch screen

Type and display

Desk type

Using PLC control system

StandardsGB/T1633, GB/T1634, ISO75, ISO306,ASTM D648, ASTM D1525,ISO 2507
UsageUsed to measure heat deformation and Vicat softening temperature of thermoplastics material of plastic and rubber in the manufacturer, scientific research and colleges.
Configuration

1. Main frame 1 set

2. Electric cabinet 1 set

3. Specimen holder 3 sets(or 3 sets)

4. Vicat indenter 3 sets

5. Heat deflection indenter 3 sets

6. Displacement sensor 3 sets

7. Power line 2 sets

8. Connecting line 2 sets

9. Operation manual 1 set

10. Certificate 1 set

11. Packing list 1 set


FAQ:

Q: What is the temperature control range and accuracy of the Vicat softening point and heat distortion testing machine?

A: The device typically covers a temperature range from ambient temperature up to 300°C (or 350°C for high-temperature models), with a temperature control accuracy of ±0.5°C, ensuring precise thermal environment control for material testing.


Q: What are the standard heating rates supported by this testing machine?

A: It complies with international testing standards and provides two common heating rates: 50°C/h (for Vicat softening point tests) and 120°C/h (for heat distortion temperature tests), with adjustable rates available for customized testing needs.


Q: What test loads can the machine apply for Vicat and heat distortion tests?

A: For Vicat tests, it supports standard loads of 10N or 50N; for heat distortion tests, the load can be adjusted within the range of 0.45MPa–1.82MPa (or customized per specific industry standards), meeting different material test requirements.


Q: What are the requirements for the size of test specimens applicable to this machine?

A: It is compatible with standard specimens for non-metallic materials: for Vicat tests, the specimen is typically 10mm×10mm×4mm (or other sizes per standards); for heat distortion tests, common specimen dimensions are 80mm×10mm×4mm, with fixtures adaptable to customized specimen sizes.


Q: What type of control system does the testing machine adopt, and what data processing capabilities does it have?

A: It is equipped with a microcomputer-controlled system and industrial-grade color HMI, which can automatically record test data (temperature, deformation, time), generate test curves in real time, and support automatic storage and printing of test reports.


Q: Does the machine have position or stroke limits for the test probe, and what is the measurement accuracy of deformation?

A: The test probe has a precise stroke limit (typically 0–10mm), and the deformation measurement accuracy is ±0.01mm, ensuring accurate capture of material thermal deformation or softening point data.


Buy HDT VICAT Tester with Automatic Needle for Testing Heat Distortion and Vicat Softening Point of Plastics Rubber and Nylon at wholesale prices