| Product List |
"Specs at a glance
Max. measurement error
Volume flow:
±3% o.r. for DN15
±2% o.r. for DN25 to 200
±2% o.r. above DN200
Measuring range
0 to 15 m/s (0 to 50 ft/s)
Medium temperature range
–40 to +130 °C (–40 to +266 °F)
Max. process pressure
N/A" "Field of application
Prosonic Flow W 400 is the ultrasonic clamp-on flowmeter of choice
for safe, cost-effective and maintenance-free measurement of
conductive and non-conductive liquids. It measures flow
noninvasively and bidirectionally, independent of pressure, density
and conductivity, and without process interruption.
FlowDC makes mounting as flexible as never before. The specified accuracy is maintained at an inlet run of only 2 x DN, even in the case of disturbed flow profiles.
Special coupling pads make this ultrasonic clamp-on system maintenance-free during the entire product life cycle.
Heartbeat Technology provides continuous process transparency with
its diagnostic, verification and monitoring functions. This way,
build-up can be detected before it affects operation." "Benefits
Flexible mounting – FlowDC reduces inlet runs to a minimum
Reliable measurement performance – proven sensors in combination with maintenance-free mounting system deliver long-term stable signals
Low capital investment – cost-effectiveness increases with the pipe diameter (up to DN 4000/160"")
User-friendly operation – the web server offers full remote access, while the device’s display offers convenient on-site interaction
Transparent process insights – Heartbeat Technology with its
integrated diagnostics, verification and monitoring functions
enable compliance and process safety at all times" "Measuring
principle
Ultrasonic flow
Product headline
Clamp-on meter with Heartbeat Technology and web server for the
water and wastewater industry.
Short inlet run thanks to FlowDC.
Bidirectional measurement for water and wastewater as well as
process water and hydropower plants.
Sensor features
Low capital investment – cost-effectiveness increases with pipe
diameter (up to DN 2000/80""). Long-term stable signal –
maintenance-free permanent mounting from outside with coupling
pads. Reliable measurement on various pipe materials – sensor for
GRP and plastic pipes available.
Mounting without process interruption. Wide nominal diameter range:
DN 15 to 4000 (½ to 160""). Medium temperature up to +130 °C (+266
°F).
Transmitter features
Safe operation – no need to open the device due to display with
touch control, background lighting. Full remote access – web
server. Integrated diagnostics, verification and monitoring –
Heartbeat Technology.
Transmitter housing made of durable polycarbonate or aluminium.
Remote version for wall mounting. Integrated data logger: measured
values monitoring.
Nominal diameter range
DN15 to 4000 (1/2 to 160"")
Sensor materials
Clamp on system:
Sensor holder 1.4301 (304), 1.4404 (316L)
Sensor housing 1.4301 (304), 1.4404 (316L)
Strapping bands 1.4301 (304), 1.4404 (316L)
Measured variables
Volume flow, Flow velocity, Sound velocity
Max. measurement error
Volume flow:
±3% o.r. for DN15
±2% o.r. for DN25 to 200
±2% o.r. above DN200
Measuring range
0 to 15 m/s (0 to 50 ft/s)
Max. process pressure
N/A
Medium temperature range
–40 to +130 °C (–40 to +266 °F)
Ambient temperature range
Sensor DN 15 to 65: -40 to 130°C
Sensor DN 50 to 4000: -40 to 130°C
Sensor housing material
N/A
Transmitter housing material
Wall-mounted housing
Polycarbonat; AlSi10Mg, coated
Degree of protection
Transmitter: IP66/67, Type 4X enclosure
Sensor: IP66/67, Type 4X enclosure, IP68, Type 6P enclosure
(optional)
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display, web browser and operating tools
possible
Outputs
3 ouputs:
4‐20 mA/4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
Pulse/frequency/switch output (passive)
Modbus RS485
Inputs
Status input
Digital communication
HART
Power supply
AC 100 to 240 V / AC/DC 24 V
Approvals
cCSAus
Other approvals and certificates
Other approvals and certificates
Product safety
CE, C-tick marking, EAC-marking
Metrological approvals and certificates
Flowmeter verification for all frequencies except 0.3 MHz,
reference line size: 5 MHz DN 50, all other frequencies DN 100
Verification performed on accredited calibration facilities (acc.
to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement
traceability according to ISO 9001:2015 – Section 7.1.5.2 a
Marine approvals and certificates
Marine approvals and certificates"
|