Sign In | Join Free | My benadorassociates.com
benadorassociates.com
Products
Search by Category
Home > Vacuum Equipment Parts >

Vertical Hwf80-04n Dehydrogenation Furnace for Modern Manufacturing Needs Package Size 1550.00cm * 1960.00cm * 1760.00cm

Categories Vacuum Muffle Furnace
Model NO.: HWF80-04N
Type: Electric Holding Furnace
Usage: Ceramic Sintering
Fuel: Electric
Atmosphere: Vacuum/Nitrogen
Effective Chamber Dimensions: 400*400*500mm(W*H*D)
Maximum Temperature: 400°c
Maximum Heating Power: 15kw
Idle Furnace Insulation Power: ≤7.5kw
Temperature Control Accuracy: ±1°c
Thermocouple Type: K-Type
Transport Package: Wooden Packaging
Specification: 1500*1950*1750mm(W*H*D)
Trademark: Chitherm
Origin: China
HS Code: 8514101000
Supply Ability: 50 Sets/Year
Package Size: 1550.00cm * 1960.00cm * 1760.00cm
Package Gross Weight: 1000.000kg
Customization: Available
Place Style: Vertical
Range of Applications: Industrial
Shipping Cost: Contact the supplier about freight and estimated delivery time.
 : Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Vertical Hwf80-04n Dehydrogenation Furnace for Modern Manufacturing Needs Package Size 1550.00cm * 1960.00cm * 1760.00cm

Vertical HWF80-04N Dehydrogenation Furnace for Modern Manufacturing Needs
Product Specifications
AttributeValue
Model NO.HWF80-04N
TypeElectric Holding Furnace
UsageCeramic Sintering
FuelElectric
AtmosphereVacuum/Nitrogen
Effective Chamber Dimensions400*400*500mm (W*H*D)
Maximum Temperature400°C
Maximum Heating Power15kW
Idle Furnace Insulation Power≤7.5kW
Temperature Control Accuracy±1°C
Thermocouple TypeK-Type
Transport PackageWooden Packaging
Specification1500*1950*1750mm (W*H*D)
TrademarkChitherm
OriginChina
HS Code8514101000
Supply Ability50 Sets/Year
Package Size1550.00cm * 1960.00cm * 1760.00cm
Package Gross Weight1000.000kg
CustomizationAvailable
Place StyleVertical
Range of ApplicationsIndustrial
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Support payments in USD. Secure payments: Every payment you make is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Product Description
I. Equipment Name and Model

HWF80-04N Type Dehydrogenation Furnace

II. Application Fields

Decarburization, dehydrogenation, annealing, tempering, degumming, and other heat treatment processes.

III. Technical Specifications and Basic Configuration
  • 3.1 Rated Temperature: 350°C (unlimited platform time)
  • 3.2 Maximum Temperature: 400°C
  • 3.3 Tank Material: SUS316L
  • 3.4 Effective Dimensions: 400×400×500mm (W×H×D)
  • 3.5 Loading Method: Manual loading, with horizontal guide rails and racks inside the tank body
  • 3.6 Heating Element: Stainless steel heating tube for internal heating
  • 3.7 Heating Method: Hot air circulation heating
  • 3.8 Maximum Heating Power: 15kW
  • 3.9 Idle Furnace Insulation Power: ≤7.5kW
  • 3.10 Temperature Rise Rate: ≤5°C/min
  • 3.11 Temperature Control Accuracy: ±1°C, with PID parameter self-tuning function
  • 3.12 Temperature Uniformity: ±5°C (350°C constant temperature test for 1 hour in an empty furnace)
  • 3.13 Thermocouple Type: K-type
  • 3.14 Number of Temperature Control Points: 1 point
  • 3.15 Temperature Measurement Method: Reserved inspection port, can install armored flexible thermocouples for real-time monitoring
  • 3.16 Number of Program Steps: 20 steps
  • 3.17 Sintering Atmosphere: Vacuum/Nitrogen
  • 3.18 Oxygen Detection: Equipped with a micro-oxygen analyzer to detect the oxygen content inside the tank body (inert atmosphere state with positive pressure inside the tank)
  • 3.19 Oxygen Content: Better than 50ppm
  • 3.20 Ultimate Vacuum Degree: 10^-2 Pa (empty furnace, clean, room temperature, fully degassed)
  • 3.21 Vacuum Pumping Time: From atmospheric pressure to 10^-2 Pa ≤60 minutes
  • 3.22 Cooling Method: Furnace cooling, cooling from 350°C to room temperature in less than 12 hours
  • 3.23 Exhaust Port: 1
  • 3.24 Surface Temperature Rise: <35°C
  • 3.25 Alarm Protection: Overtemperature, thermocouple breakage, low air pressure, low water pressure, motor under-voltage and other sound and light alarm protections, with overtemperature alarm cut-off heating protection function
  • 3.26 Equipment Weight: About 1000kg
  • 3.27 Equipment Color: Light gray
  • External Reference Dimensions: 1500×1950×1750mm (W×H×D), specific dimensions subject to actual product
IV. Delivery List
ItemNoteQty.
Basic ComponentsFurnace1 Unit
Inspection CertificateCertificate of major outsourced components1 Set
Technical DocumentsInstructions, technical documents of the major outsourced parts, etc1 Set
Key ComponentsHeating ElementResistance wire pre-built heating plate
Mechanical PumpBusch DRV601 Unit
Molecular PumpZhongke Keyi FF-2001 Unit
Vacuum Gauge + RegulatorRuibao1 Set
Oxygen AnalyzerNanoaonai1 Unit
Touch Screen1 Unit
Mass Flow MeterPrecise Measurement1 Unit
Temperature ControllerAzbil or equivalent brand1 Set
ThermocoupleType K3 Pcs
PLCSIEMENS or equivalent brand1 Unit
Spare PartsSSR1 PC
Sealing ringFluororubber1 Piece
V. Normal Operation Conditions of the Equipment
  • 5.1 Environmental Conditions: Temperature 0~40°C, humidity ≤80%RH, no corrosive gases, no strong airflow disturbance
  • 5.2 Nitrogen Conditions: Gas source pressure 0.2~0.4Mpa, purity 99.999%, gas consumption 2~6m3/h
  • 5.3 Conducting Air Source Conditions: Clean, dry, oil-free compressed air, pressure 0.4~0.8Mpa
  • 5.4 Water Supply Conditions: 0.1~0.3Mpa, clean, non-corrosive, supply flow rate 1~3L/min
  • 5.5 Ventilation System: Non-contact connection to user's exhaust system, exhaust capacity greater than 10m3/h
  • 5.6 Floor Requirements: Level, no significant vibration, load-bearing capacity >500kg/m2
  • 5.7 Power Conditions: Capacity greater than 22kVA, 3-phase 5-wire, voltage 220/380V, frequency 50Hz. Live wires: Yellow, Green, Red; Neutral wire: Blue; Earth wire: Yellow-green
  • 5.8 Installation Site: 3000mm×2500mm×3000mm (D×W×H), installation area greater than 8m2
HWF80-04N Dehydrogenation Furnace installation diagram
Buy Vertical Hwf80-04n Dehydrogenation Furnace for Modern Manufacturing Needs Package Size 1550.00cm * 1960.00cm * 1760.00cm at wholesale prices
Send your message to this supplier
 
*From:
*To: Hefei Chitherm Equipment Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0