Mindray BA-88A Semi-Automated Biochemistry Analyzer for Routine Clinical Chemistry Tests​​

Categories Medical Analyzer
Brand Name: Mindray
Model Number: BA-88A
Certification: CE
Place of Origin: CHINA
MOQ: 1PCS
Price: Negotiable
Payment Terms: L/C,T/T,Westen Union,Money Gram,Paypal/VTB
Supply Ability: 1000pcs/month
Delivery Time: 10-15days
Packaging Details: Carton
Product name: Semi-Automated Biochemistry Analyzer
Absorbance range: 0-2.5 A
Stability: < 0.005A/20min
Test speed: Up to 300 tests per hour
Suction volume: Adjustable from 200 μl to 9000 μl
Display screen: 7.0-inch TFT touch screen
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Mindray BA-88A Semi-Automated Biochemistry Analyzer for Routine Clinical Chemistry Tests​​

Description


The Mindray BA-88A Semi-Automated Biochemistry Analyzer is a versatile and reliable instrument designed for efficient clinical biochemistry testing in small to medium-sized laboratories. Here is a detailed description of Semi-Automated Biochemistry Analyzer's features and capabilities.
The Mindray BA-88A is a semi-automated biochemistry analyzer engineered to perform quantitative analysis of various biological samples, including serum, plasma, urine, and cerebrospinal fluid . Semi-Automated Biochemistry Analyzer combines an open-system architecture with user-friendly operation, supporting a wide range of clinical chemistry tests such as liver function, kidney function, lipids, myocardial enzymes, and electrolyte panels . Its design emphasizes accuracy, operational efficiency, and adaptability to diverse laboratory workflows .

​​Key Features and Technical Specifications​​

  • ​​Analytical Methods and Flexibility​​: The analyzer supports multiple testing methodologies, including endpoint, kinetic, two-point kinetic/fixed-time, and absorbance testing modes. It features linear and nonlinear calibration and operates using single or dual wavelengths for enhanced accuracy .
  • ​​Optical System and Measurement​​: Equipped with a halogen tungsten lamp (6V/10W) , it offers a wavelength range of 340-700 nm and an photometric range of 0 to 2.5 Abs . It utilizes both a flow cell (32μl) and discrete quartz cuvettes for measurements .
  • ​​Temperature Control and Sample Handling​​: The instrument provides precise temperature control with selectable settings at 25°C, 30°C, 37°C, and room temperature, maintained by a Peltier system to ensure reaction stability . The sample volume is adjustable from 200μl to 9000μl .
  • ​​User Interface and Data Management​​: It features a 7-inch TFT touchscreen for intuitive operation and allows connection of external mouse or keyboard via USB ports . The system can store over 3,000 patient results and 1,000 quality control results, facilitating easy data tracking and management .
  • ​​Quality Control and Calibration​​: The BA-88A includes comprehensive quality control functions, support for multi-rule QC, and displays Levey-Jennings charts . Its open-system design allows users to freely modify and save test parameters for up to 200 items .

​​Intended Applications​​

This analyzer is well-suited for a variety of healthcare settings, from primary to tertiary hospitals, particularly in clinical laboratories and testing departments . Its key applications include:
  • ​​Routine Biochemistry​​: Performing essential tests for liver function (ALT, AST, ALP), kidney function (BUN, Creatinine, Uric Acid), lipids (Cholesterol, Triglycerides), and glucose .
  • ​​Specialized Testing​​: Capable of conducting specific protein assays and electrolyte analysis .
  • ​​Efficiency in Testing​​: The analyzer can achieve a throughput of up to 120 tests per hour, enhancing laboratory productivity .

​​Primary Advantages​​

  • ​​Operational Efficiency​​: The combination of a touchscreen interface, pre-programmable test parameters, and dual measurement modes (flow cell and cuvette) streamlines the testing process .
  • ​​Accuracy and Reliability​​: Features like dual-wavelength testing and automatic correction for reagent blanks effectively minimize interference, ensuring result accuracy . The Teflon-coated fluidic system reduces carryover contamination .
  • ​​Low Maintenance and Cost-Effectiveness​​: The instrument requires minimal daily maintenance and is compatible with a wide range of domestic and imported reagents, offering laboratories flexibility and cost savings .
The Mindray BA-88A Semi-Automated Biochemistry Analyzer effectively balances performance, ease of use, and adaptability, making it a practical and valuable asset for clinical laboratories aiming to deliver reliable diagnostic services.


Specification


Wavelength range340-670 nm
Result storage≥ 3,000 sample test results, ≥ 1,000 quality control results
Project parameter storage≥ 200 test project parameters
Light sourceHalogen tungsten lamp (6V / 10W)
Reaction temperatures25°C, 30°C, 37°C and room temperature
Power supply100V-240V~, 50/60Hz