| Sign In | Join Free | My benadorassociates.com |
|
| Categories | EV Battery Testing Equipment |
|---|---|
| Brand Name: | Sinuo |
| Model Number: | SN551 |
| Certification: | Calibration Certificate (Cost Additional) |
| Place of Origin: | China |
| MOQ: | 1 |
| Payment Terms: | T/T |
| Supply Ability: | 10 Sets Per Month |
| Delivery Time: | 30 Days |
| Packaging Details: | Export packing |
| Max. load current: | 2000A (DC) |
| Built-in resistor: | 20±5mΩ and 80±20mΩ |
| Inner chamber size: | W650mm*D650mm*H500mm |
| DC response time: | ≤5μs |
| Voltage collection range: | 0~100V (DC) |
| Current acquisition rate: | 1 time/S |
| Temperature collection range: | 0~100℃ |
| Temperature collection accuracy: | ±2℃ |
| Company Info. |
| Sinuo Testing Equipment Co. , Limited |
| Verified Supplier |
| View Contact Details |
| Product List |
It is conforms to the standard of UL 2580 clause 26, IEC62133-1:2017 clause 7.3.2 , IEC62133-2:2017 clause 7.3.1 and 7.3.2 , IEC62133:2014 clause 7.3.2,8.3.1, 8.3.2, IEC60086-4 clause 6.5.1, IEC60086-4 clause 6.5.8 6.5.9 , and so on .
| Name | Parameters | |
|---|---|---|
| Max. load current | 2000A (DC) | |
| DC response time | ≤5μs | |
| Built-in resistor | 20±5mΩ and 80±20mΩ (Two sets of resistors, can be manually switched based on different standard requirements) | |
| Inner chamber size | W650mm*D650mm*H500mm | |
| Control method | PLC and Touch screen | |
| Inner box material | Stainless steel | |
| Sealing strip | Corrosion-resistant silicone. | |
| Temperature control | Normal temperature RT+10℃~100℃ (can be preset) Temperature rise rate 3℃/min Temperature dial 0.5℃ Temperature uniformity: ±2℃ | |
| Test stop condition | 1) The battery temperature drops to 20% lower than the peak; 2) Short circuit time | |
| Battery surface temperature | Can monitor temperature changes during battery surface testing | |
| Sample rack | Stainless steel SUS #201 perforated steel plate storage rack, with a maximum load-bearing capacity of 30KG on a single layer. The height is adjustable at the same time. | ![]() |
| Hall element collects current signal | Hall elements are used to collect the current generated when the short-circuit system is short-circuited, avoiding the generation of contact resistance, and the data transmission is stable and accurate; | ![]() |
| Lead hole | There is a lead hole with a diameter of 50mm on the left side of the box for test wires to pass through. | ![]() |
| Chamber door | High-strength hinges are used to fix the door, and at least 2 sets of explosion-proof locks can be installed on the door to fix it. | |
| Explosion-proof pressure relief device | It has the function of exhaust, explosion-proof and pressure relief. The rear of the protective box has a magnet-adsorbed pressure relief door (300*300mm). When strong airflow impacts, the pressure relief door automatically opens and closes to reduce the impact of the explosion. | |
| Lighting | The test chamber door is designed with high-brightness LED lighting to make it easy to see the test conditions in the test chamber. | |


|