Sign In | Join Free | My benadorassociates.com
benadorassociates.com
Products
Search by Category
Home > Measuring & Analysing Instrument Design Services >

Anti-interference Trip-proof Light ON/OFF Motion Sensor, Support Front Dip Switch And Remote Configuration

Categories On Off Function Sensor
Brand Name: Merrytek
Model Number: MC098S 2 RC
Certification: CE, RED
Place of Origin: Shenzhen, China
MOQ: 100pcs
Price: Negotiable
Payment Terms: T/T
Supply Ability: 10000 pcs/month
Delivery Time: 1, Sample and small order: Within 5 working days after receiving your payment. 2, Bulk order: 4-5 weeks after receiving deposit.
Packaging Details: Bubble bag+Clapboard + Carton(K=A)
Rated Voltage: 220-240V AC, 50Hz/60Hz
Stand-by Power: ≤0.5W
Load Capacity: 400W (Inductive) ; 800W (Resistive)
Mounting Height: 2.5-6m
Operating Temperature: -25℃…+60℃
Lifetime: 5 years warranty @Ta 230V full load
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Anti-interference Trip-proof Light ON/OFF Motion Sensor, Support Front Dip Switch And Remote Configuration


1. Features


  • Low Impedance sensor antenna patent helps anti-interference kinds of wireless signal like 5G, Wi-Fi, Bluetooth etc.
  • Patented dipole antenna design brings reliable detecting, avoid false trigger when sensor built-in backside of metal LED plate.
  • Comply with RED approval.
  • Non-isolated switching power supply, will not affect the PF value of the whole lamp, in accordance with the latest ERP.
  • Adjustable detecting sensitivity via DIP switches, suitable to variety of installation sites.
  • Ultra-slim design for Tri-proof LED light
  • Support 6m Max. Mounting height .
  • Dialing code and remote control are both supported for parameters setting.
  • 5 years warranty.

2. Parameter


InputOperating Voltage Rage120-277V AC 50Hz/60Hz
Rated Voltage220-240V AC, 50Hz/60Hz
Stand-by Power≤0.5W
Surge TestL--N: 1kV
OutputWorking ModeON/OFF function
Type of LoadInductive or Resistive
Load Capacity400W (Inductive) ; 800W (Resistive)
Max. Surge Capacity

10A relay;

30A (50% Ipeak, twidth =500uS, 230Vac full load, cold start);

Sensor ParametersOperating Frequency5.8 GHz ±75 MHz,ISM Band.
Transmitting power0.5mW Max.
Hold time

5S/30S/90S/5Min (by two dialing codes)

10S/90S/3Min/10min (by remote MH03)

Detection Sensitivity

100%/75%/50%/25% (by two dialing codes)

100%/50% (by remote MH03)

Daylight Sensor

25lux/Disable (by one dialing code)

5lux/15lux/50lux/Disable (by remote MH03)

Detecting Radius>3m (mounting height 3-4m) ; >2m (mounting height 6m) ;
Mounting Height2.5-6m, and 4m is of the max. detecting radius
Detecting Angle150° (Wall mounted)

Operating

Environment

Operating Temperature-25℃…+60℃
Storage Temperature-40℃…+80℃ (Humidity: 10%-95% Non-condensing)
Certificate StandardsSafety standardsEN61058-1
EMC standardsEN300440; EN301489-1; EN55015; EN61547; EN61000-3-2; EN61000-3-3; EN62479
Environmental RequirementCompliant to RoHS
CertificateCE, RED
OthersWiringPress-in Type Terminals, wire diameter:0.75-1.5mm2
IP RatingIP20
Protection ClassClass II
InstallationBuilt-in
Dimension77.5*34.5*22mm
PackageBubble bag+Clapboard + Carton(K=A)
Net Weight45±3g
Lifetime5 years warranty @Ta 230V full load

Note

1. “N/A”means not available.

2. Detection area is effected on volume of motion object and motion speed. The detection area is tested by a 165cm height person and walking speed is 1m/s.

InputOperating Voltage Rage120-277V AC 50Hz/60Hz
Rated Voltage220-240V AC, 50Hz/60Hz
Stand-by Power≤0.5W
Surge TestL--N: 1kV
OutputWorking ModeON/OFF function
Type of LoadInductive or Resistive
Load Capacity400W (Inductive) ; 800W (Resistive)
Max. Surge Capacity

10A relay;

30A (50% Ipeak, twidth =500uS, 230Vac full load, cold start);

Sensor ParametersOperating Frequency5.8 GHz ±75 MHz,ISM Band.
Transmitting power0.5mW Max.
Hold time

5S/30S/90S/5Min (by two dialing codes)

10S/90S/3Min/10min (by remote MH03)

Detection Sensitivity

100%/75%/50%/25% (by two dialing codes)

100%/50% (by remote MH03)

Daylight Sensor

25lux/Disable (by one dialing code)

5lux/15lux/50lux/Disable (by remote MH03)

Detecting Radius>3m (mounting height 3-4m) ; >2m (mounting height 6m) ;
Mounting Height2.5-6m, and 4m is of the max. detecting radius
Detecting Angle150° (Wall mounted)

Operating

Environment

Operating Temperature-25℃…+60℃
Storage Temperature-40℃…+80℃ (Humidity: 10%-95% Non-condensing)
Certificate StandardsSafety standardsEN61058-1
EMC standardsEN300440; EN301489-1; EN55015; EN61547; EN61000-3-2; EN61000-3-3; EN62479
Environmental RequirementCompliant to RoHS
CertificateCE, RED
OthersWiringPress-in Type Terminals, wire diameter:0.75-1.5mm2
IP RatingIP20
Protection ClassClass II
InstallationBuilt-in
Dimension77.5*34.5*22mm
PackageBubble bag+Clapboard + Carton(K=A)
Net Weight45±3g
Lifetime5 years warranty @Ta 230V full load

Note

1. “N/A”means not available.

2. Detection area is effected on volume of motion object and motion speed. The detection area is tested by a 165cm height person and walking speed is 1m/s.

InputOperating Voltage Rage120-277V AC 50Hz/60Hz
Rated Voltage220-240V AC, 50Hz/60Hz
Stand-by Power≤0.5W
Surge TestL--N: 1kV
OutputWorking ModeON/OFF function
Type of LoadInductive or Resistive
Load Capacity400W (Inductive) ; 800W (Resistive)
Max. Surge Capacity

10A relay;

30A (50% Ipeak, twidth =500uS, 230Vac full load, cold start);

Sensor ParametersOperating Frequency5.8 GHz ±75 MHz,ISM Band.
Transmitting power0.5mW Max.
Hold time

5S/30S/90S/5Min (by two dialing codes)

10S/90S/3Min/10min (by remote MH03)

Detection Sensitivity

100%/75%/50%/25% (by two dialing codes)

100%/50% (by remote MH03)

Daylight Sensor

25lux/Disable (by one dialing code)

5lux/15lux/50lux/Disable (by remote MH03)

Detecting Radius>3m (mounting height 3-4m) ; >2m (mounting height 6m) ;
Mounting Height2.5-6m, and 4m is of the max. detecting radius
Detecting Angle150° (Wall mounted)

Operating

Environment

Operating Temperature-25℃…+60℃
Storage Temperature-40℃…+80℃ (Humidity: 10%-95% Non-condensing)
Certificate StandardsSafety standardsEN61058-1
EMC standardsEN300440; EN301489-1; EN55015; EN61547; EN61000-3-2; EN61000-3-3; EN62479
Environmental RequirementCompliant to RoHS
CertificateCE, RED
OthersWiringPress-in Type Terminals, wire diameter:0.75-1.5mm2
IP RatingIP20
Protection ClassClass II
InstallationBuilt-in
Dimension77.5*34.5*22mm
PackageBubble bag+Clapboard + Carton(K=A)
Net Weight45±3g
Lifetime5 years warranty @Ta 230V full load

Note

1. “N/A”means not available.

2. Detection area is effected on volume of motion object and motion speed. The detection area is tested by a 165cm height person and walking speed is 1m/s.


3. Function


On/OFF Function


5. Wiring


*The sensor is designed for connect one load only. Connect more than one loads may damage the sensor.


6. Structure



7. Remote Control(MH03)


12
100%ONON
75%-ON
50%ON-
25%--

Hold Time


34
ONON5S
-ON30S
ON-90S
--5min

Daylight Sensor


5
ON25Lux
-Disable

*Disable” means the daylight sensor not work. it will turn on light once motion is detected regardless of ambient light.


9. Override Function


Power off, quick switch ON/OFF sensor 3 times (ON-OFF-ON-OFF-ON) within 2sec to override sensor function. Lights will blink 3 times and then switch ON all the time. Power off and on again to recover sensor function.


10. Initialization


After power on, the sensor automatically turns on light at 100% brightness. After 10sec, it turns off the light. During the initialization, the sensor is not able to detect movement.


11. Factory Setting


Detection area: 100%, Hold Time: 5S, Daylight Sensor: Disable


12. Application Notice


1) The sensor should be installed by a professional electrician. Please turn off the power before installing, wiring, changing the setting of the DIP switch.

2) The sensor which installed in the plastic and glass lampshade will reduce the sensitivity.For every 3mm increase in thickness, the sensitivity will be reduced by 20%.

3) The light sensitivity threshold is in a sunny environment, no shadow and ambient light diffuse reflection.Ambient lux level will be different in different environment, weather, climate, time-of-day and season.

4) The parameters of the sensor may need to be reconfigured in different installation environments.

5) This sensor is for indoor use only. It will affect the waterproof effect for outdoor use. Wind, rain, and moving objects around will cause false triggering.

6) The distance between any inductive sensors should be greater than 3m.

7) Do not place the sensor close to high-density objects such as metal, glass,concrete walls, etc, false triggering could happen. When the sensor is installed in a metal lamp, metal reflective surface, or a narrow enclosed

environment, the microwave will be reflected repeatedly and cause false triggering. Please reduce the sensitivity or contact the manufacturer for technical support.

8) Please ensure that there are no moving signals around the sensor, such as fan,DC motor, sewer pipe, air outlet, etc., the sensor may generate false trigger.

9) You are advised to test 5 samples before mass application of sensor in a new lighting project.

10) Due to continuous improvement, the contents of this instruction could be changed without prior notice.

11) If the sensor is built under metal board ,make sure the sensor surface should to be seamless close to the metal plate without space .


Buy Anti-interference Trip-proof Light ON/OFF Motion Sensor, Support Front Dip Switch And Remote Configuration at wholesale prices
Send your message to this supplier
 
*From:
*To: Shenzhen Merrytek Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0