| Mechanical |
| 1. Connection Force | Measured after connecting and disconnecting using standard plug
gauge 3 times. | 3~20N | |
| Disconnect Force | Measured after connecting and disconnecting using standard plug
gauge 3 times. | 3~20N | |
| 2. Terminal Strength | A static load of 0.1N/m(1kgf/cm) shall be applied to the tip of the
terminal for 1 min in any direction. There shall be no damage to
the terminal such as cracks, looseness or play. Electrical, and
mechanical characteristics shall be satisfied. | | |
| Electrical |
| 3.1 Contact Resistance | Measured at small current (100mA or less) 1000Hz | 0.03 | |
| 3.2 Insulation Resistance | Apply a voltage of 500V DC for 1 min to following portions after
which measurement shall be made: (1) Between body and conductor (2)
Between conductors not to be contact (3) Between conductors not to
be when plug is inserted | 100M | |
| 3.3 Dielectric Strength | AC 500V rms(50~60Hz) for 1 min trip current:0.5mA (1) Between body
and conductor (2) Between conductors not to be contact (3) Between
conductors not to be when plug is inserted | Without damage to parts arcing or breakdown etc. | |
| Durability |
| 4.1 Solderability Test | The top of the terminals shall be dipped 1mm in the solder bath of
2405 for 30.5 seconds. (1) Solder wetting time shall be 3 sec or
less (2) The area of soldering should be over 75% | | |
| 4.2 Resistance to Soldering Heat Test | Soldering iron method: Bit temperature 3305 Application time of
soldering iron 30.5 sec. However excessive pressure shall not be
applied to the terminal. | Without deformation of case or excessive looseness of terminals.
Electrical characteristics shall be satisfied. | |
| 4.3 Humidity Test | The jack shall be stored at a temperature of 402 and a humidity of
90% to 96% for 96 Hr, then the jack shall be maintained at standard
atmospheric condition for 1 Hr for other procedures. | There shall be no damage on appearance. Mechanical and electrical
characteristics shall be satisfied. | |
| 4.4 Heat Test | The jack shall be stored at a temperature of 702 for 96 hours, and
then it shall be subjected to the controlled recovery measurement. | | |
| 4.5 Cold Test | The jack shall be stored at a temperature of -253 for 96 hours and
then it shall be subjected to the controlled recovery conditions
for 1 hour after which. | There shall be no damage on appearance. Mechanical and electrical
characteristics shall be satisfied. | |
| 4.6 Life Test | Without load: Connection and disconnection shall be made with the
mating plugs and jacks for 5,000 cycles at a speed of 10 to 25
cycles/min. Load: At rating condition (non-inductive load)
connection and disconnection shall be made 1,000 cycles at a speed
10 to 20 cycles/min. (1) Contact Resistance shall be 0.1 (2)
Disconnection Force shall be 3 to 20N (3) Mechanical and Electrical
Characteristics shall be satisfied. | | |
| 4.7 Temperature Cycling Test | The jack shall be subjected to 5 cycles of the following
conditions, and then shall be returned allowed to remain in room
ambient condition for 30 minutes. Temp(): 60 to -40. Time (hour):
0, 2, 4, 6. | There shall be no deformation or cracks in molded part. Insertion &
Extraction Force: 3 to 20N. Contact Resistance: Max. 30m.
Insulation Resistance: Min. 100 M. Dielectric Withstanding Voltage:
500VAC/min (between terminals). | |
| 4.8 Heat Shock Test | The jack shall be subjected to 6 cycles of the following
conditions, and then shall be returned and allowed to remain in
room ambient condition for 30 minutes. Temp (): 60 to -10.
Time(hour): 0, 1, 2, 3. | There shall be no deformation or cracks in molded part. Insertion &
Extraction Force: 3 to 20N. Contact Resistance: Max. 30m.
Insulation Resistance: Min. 100 M. Dielectric Withstanding Voltage:
500VAC/min (between terminals). | |