| Sign In | Join Free | My benadorassociates.com |
|
| Categories | Paperless Recorder |
|---|---|
| Brand Name: | TOPRIE |
| Model Number: | T3 |
| Certification: | CE,ROHS |
| Place of Origin: | China |
| MOQ: | 1 piece |
| Payment Terms: | Western Union,T/T,D/P,D/A,L/C |
| Supply Ability: | 100 piece per day |
| Delivery Time: | 5-8 work days |
| Packaging Details: | Packed in paper box |
| Company Info. |
| SHENZHEN TOPRIE ELECTRONICS CO.,LTD. |
| Verified Supplier |
| View Contact Details |
| Product List |
The T3 Wireless data acquistion, independently manufactured by Toprie, supports the simultaneous measurement of temperature, humidity, current, voltage, pressure, liquid level, flow rate, displacement and other parameters. Featuring a minimalist design, it is compact and user-friendly, and enables wireless remote transmission of data to computers (via Internet Explorer) as well as mobile phones and WeChat for real-time monitoring.

Acquisition Selection
| Name | Model | Channel Quantities | Description |
|---|---|---|---|
| Universal input signal acquisition card | TP1708P2.1 | 8CH | Thermocouple: K/T/J//E/S/R/N/B/WRe3/WRe5 Thermal resistor: PT100/PT1000 DC Voltage: 0-5V / 0-10V / ±100mV / ±20mV DC current: 4-20mA / 0-20mA Sampling speed: 1s |
| Universal input signal acquisition card (0.1s) | TP1708P1 | 8CH | Thermocouple: K/T/J//E/S/R/N/B/WRe3/WRe5 Thermal resistor: PT100/PT1000 DC Voltage: 0-5V / 0-10V / ±100mV / ±20mV DC current: 4-20mA / 0-20mA Sampling speed: 0.1s |
| DC voltage acquisition card | TP1758 | 8CH | DC voltage measurement: 0-120V accuracy: 0.5%, resolution: 1mV (Customized range 0-300V) |
| Multiple current acquisition card | TP1748 | 8CH | DC current measurement: 0-10A accuracy: 0.5%, resolution: 1mA (Customized large current) |
| AC DC power acquisition card | TP1706V1 | 1 | Single phase AC and DC power, including voltage/current/power/frequency/power factor/KWh etc., voltage range: 5~1000V, current 10mA~20A, frequency: 45Hz~400Hz |
| Three phase power acquisition card | TP1707 | 1 | Three phase AC and DC power, including
voltage/current/power/frequency/power factor/KWh etc., voltage
range: 5~1000V, current: 1A~1000A / 1mA~20A, frequency: 1Hz~400Hz Remark: 1~1000A (Rogowski coil current transformer); 1mA~20A (large
ratio current transformer) |
| Temperature and humidity acquisition card | TP1728 | 8 | TP2305V2 temperature and humidity probe |
| Relay acquisition card | TP1708J | 8 | 8 channel normal open or close relay contact output overload 250V 2A |
| Switch quantities acquisition card | TP1708K | 8 | 8CH switch quantities signal input, wet contact 5~24V |
| NTC temperature acquisition card | TP1708N | 8 | NTC temperature sensor, including 3600/3950/3425/3435/other specification can be customized |
Accuracy List
| Input Type | Measuring Range | Measuring Accuracy | Display Resolution |
|---|---|---|---|
| 0-10V | -0.5V ~ +11.000V | 0.01% F.S ± 0.002V | Maximum 6 digit display |
| 0-5V | -0.5V ~ +5.500V | 0.01% F.S ± 0.002V | |
| ±20mV | -21mV ~ +21mV | 0.005% F.S ± 0.005mV | |
| ±100mV | -110.0mV ~ +110.0mV | 0.005% F.S ± 0.005mV | |
| 4-20mA | +3.00mA ~ +21.00mA | 0.01% F.S ± 0.001mA | |
| 0-20mA | +0.00mA ~ +21.00mA | 0.01% F.S ± 0.001mA | |
| K | -200℃ ~ +1372℃ | ±(0.1% rdg. + 1.0℃) | Maximum 6 digit display |
| J | -200℃ ~ +1200℃ | ±(0.1% rdg. + 1.0℃) ≤0 ±(0.15% rdg. + 1.0℃) | |
| E | -200℃ ~ +1000℃ | ±(0.1% rdg. + 1.0℃) ≤0 ±(0.15% rdg. + 0.5℃) | |
| T | -200℃ ~ +400℃ | ±(0.1% rdg. + 1.0℃) ≤-30℃ ±(0.15% rdg. + 0.5℃) | |
| N | -200℃ ~ +1300℃ | ±(0.1% rdg. + 1.0℃) ≤0 ±(0.3% rdg. + 0.7℃) | |
| W | +1500℃ ~ +2315℃ 0℃ ~ +1500℃ | ±(0.05% rdg. + 1.5℃) ±(0.05% rdg. + 1.0℃) | |
| R | +800℃ ~ +1768℃ +400℃ ~ +800℃ | ±(0.05% rdg. + 1.5℃) ±(0.2% rdg. + 2.0℃) | |
| S | +800℃ ~ +1768℃ +400℃ ~ +800℃ | ±(0.05% rdg. + 1.5℃) ±(0.2% rdg. + 2.0℃) | |
| B | +800℃ ~ +1820℃ +400℃ ~ +800℃ | ±(0.05% rdg. + 1.5℃) ±(0.2% rdg. + 2.0℃) | |
| Pt100 | -200℃ ~ +660℃ | ±(0.02% rdg. + 0.3℃) | |
| Pt1000 | -200℃ ~ +300℃ | ±(0.02% rdg. + 0.2℃) | |
| Cu50 | -50℃ ~ +150℃ | ±(0.02% rdg. + 0.3℃) | |
| Warmup time: over 30 Mins | |||
| Thermocouple measurement: including cool compensation accuracy | |||
| Operation (listed accuracy): under Temperature: 25℃ ±3℃ humidity: 55% ±10% RH | |||
| Storage: -20℃ ~ 50℃ 0-90% RH (No condensing) | |||
Advantages
It supports the connection of multiple types of signal sensors, enabling the simultaneous testing of parameters including temperature, voltage, humidity, pressure, flow rate, liquid level, current, frequency, vibration, rotational speed and others.
Application
The T3 wireless data acquisition is widely used in such fields as power and electrical engineering, biopharmaceuticals, electronic testing, new energy, transportation, meteorology, environmental protection, agriculture, and various other industrial sectors.
FAQ
|