Product Description
Thank you for selecting our product. Before using this meter,
please carefully read this Manual. It will instruct you on correct
operation methods and simple examination and handling essentials so
you can benefit from its advantages. This instrument is a precision
instrument for measuring the intensity of solar infrared radiation.
It is applied to the radiation intensity measurement of infrared
sources (sun, infrared lamps, etc.), the resistance performance
test for infrared light (thermal insulation performance test) of
building and automotive insulation glass, thermal insulation film
etc, the energy test of infrared bath, infrared physiotherapy lamp,
infrared electric heater. Infrared light sources are often used for
heating, physiotherapy, night vision, communication, navigation,
plant cultivation and poultry breeding, etc.
Product Parameters
Performance characteristics
* 4 1/2 digital display
* Data retention function
* Wide measure range without adjustment
Technical specifications
Resolution: 1W/m²
Error range: ± (10%R+2dgts) R:readings
Temperature error: ±0.38W/m² / deviation at 25
Display: 4 1/2 LCD display, maximum displayed numerical value
19999, over load "OL" Drift:
>>