| Sign In | Join Free | My benadorassociates.com |
|
| Categories | Fire Detection Tube |
|---|---|
| Brand Name: | XINGJIN |
| Model Number: | WZ-Q/T-QZ3-XJ60 |
| Certification: | GSG\TUV\GB6653-2008 |
| Place of Origin: | Guangzhou,China |
| MOQ: | 100 set system |
| Price: | Pricing based on quantity |
| Payment Terms: | T/T,L/C |
| Supply Ability: | 30000set/month |
| Delivery Time: | 15-20days |
| Packaging Details: | Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper |
| Density: | 1 |
| Melting point temperature: | 1 |
| Nominal working pressure: | 5 |
| Maximum working pressure: | 1 |
| Maximum length of fire detection tube: | 2 |
| Company Info. |
| Guangzhou Xingjin Fire Equipment Co.,Ltd. |
| Verified Supplier |
| View Contact Details |
| Product List |
FM200 Direct-type Fire Detector Tube
Product Introduction:
FM200 Fire Trace Tube is a compact and highly efficient automatic fire suppression system designed for enclosed and high-risk environments such as electrical cabinets, server racks, and control panels. Utilizing clean agent FM200 (HFC-227ea), the system ensures rapid fire detection and suppression without residue, damage, or downtime.
The system integrates fire detection and extinguishing in one unit through a pressurized tube. When exposed to heat or flame, the tube bursts at the hottest point and releases FM200 directly onto the fire source—achieving precise, automatic fire suppression without electricity or manual intervention.
Main parameters of the fire probe tube:
| Outer diameter | Inner diameter | Wall thickness | Density | Melting point temperature |
| Φ6mm | Φ4mm | 1.0mm±0.1mm | 1.05g/cm3 ±0.1g/cm3 | 170℃±10℃ |
Device technical parameters:
| Device type | Device release type | Nominal working pressure | Maximum working pressure | Operating temperature range | The minimum amount of fire extinguishing agent required per unit volume | The maximum length of the fire probe tube | Maximum length of the release tube | Maximum filling coefficient |
| Heptafluoropropane temperature-sensitive automatic fire extinguishing device | Direct form | 2.5Mpa | 4.2Mpa | (-10~50)℃ | 0.7kg/m3 | 25m | -- | 1.12kg/L |
Device type and model:
| Device type | Model specification | Fire extinguishing agent filling volume(kg) | Effective protection scope(m3) | The maximum length of the fire probe tube(m) | Maximum length of the release tube(m) | Device Release Type |
| Heptafluoropropane temperature-sensitive automatic fire extinguishing device | WZ-Q/T-QZ3-XJ60 | 3 | 4.2 | 25 | -- | Direct form |

Performance Characteristics:
First, the fire extinguishing agent delivery tube has the functions
of fire detection, fire extinguishing device activation, and fire
extinguishing agent release, eliminating the need for fire alarm
and detection devices, thereby reducing costs and installation
difficulties, and greatly improving the reliability of the fire
extinguishing device, avoiding the false operation of electrical
control alarm components.
Second, this device only implements full-coverage fire
extinguishing for equipment that has already caught fire, and
quickly extinguishes the fire in a point-to-point manner, changing
the situation where traditional gas fire extinguishing systems
extinguish the entire equipment space regardless of the size of the
fire, resulting in slow detection response time and excessive use
of fire extinguishing agents.
Third, the fire detection tube can be laid inside equipment and
instruments that may catch fire, enabling the fastest detection of
fires and the fastest point-to-point fire suppression for only the
burning parts, resulting in faster response time, less fire
extinguishing agent consumption, lower costs, and greater
environmental friendliness.
From the above three characteristics of the temperature-sensing
self-starting fire extinguishing device, it can be seen that it is
a more scientific fire extinguishing method in terms of improving
fire extinguishing efficiency, saving costs, and environmental
protection compared to current fixed fire extinguishing devices,
especially solid gas fire extinguishing devices.
Technical Specifications:
Agent Type: FM200 (HFC-227ea)
System Type: Direct / Indirect Fire Trace Tube
Agent Capacity: 2kg / 3kg / 4kg / 6kg / 9kg / 12kg
Working Pressure: 2.5 MPa
Max Pressure: 4.2 MPa
Working Temperature: 0°C – 50°C
Detecting Tube Length: 5m – 25m
Releasing Tube Length: 0.5m – 1.5m
Density: 0.7 kg/m³
System Application Scope:
The temperature-sensing automatic fire extinguishing device has
solved the long-standing problem in the fire protection field
regarding the prevention of fires in spaces such as electrical
equipment, control boxes, and distribution boards that are prone to
fire. Currently, this device has been widely applied in domestic
systems such as power plants, communications, broadcasting and
television, petrochemicals, railways, etc., and has accumulated a
large amount of successful experience.
1. Suitable for extinguishing fires in the following places:
Microwave rooms, decimeter wave rooms, meter wave rooms, power
distribution rooms and uninterruptible power supply rooms in radio
and television stations; Switching exchange rooms, control rooms
and signaling transfer point rooms of communication systems;
Control rooms, electronic equipment rooms, computer rooms, relay
rooms, power distribution rooms of power plants; Locations such as
cable intersections, dense areas and intermediate joints; Power
distribution cabinets, elevator control cabinets, cable trays with
troughs or bridges; Special or important cabinet equipment with
relatively enclosed enclosures in other places.
2. Types of fires that can be extinguished
2.1 The automatic fire extinguishing device filled with
heptafluoropropane can be used to extinguish the following fires:
Flammable gas fires that can cut off the gas source before
extinguishing;
Fire of Class A, B and C liquids or molten solids such as paraffin
and asphalt;
Surface fires of solids and partial deep-position fires of cotton,
wool, paper and other solid materials;
Electrical fires.
2.2 The automatic fire extinguishing device filled with
heptafluoropropane shall not be used to extinguish the following
fires:
Fires of chemical products containing oxidants such as
nitrocellulose, gunpowder;
Fires of active metals such as potassium, sodium, magnesium,
titanium, zirconium;
Fires of metal hydrides such as potassium hydride, sodium hydride.
FAQ:
Q: Are you a trading company or a manufacturer?
A: We are both a manufacturer and a trading company. We have owned
our own factory for nearly 15 years and are committed to providing
high-quality service to our overseas customers.
Q: Can you do OEM production?
A: We accept all OEM orders. Simply contact us with your design
proposal, and we will provide you with a reasonable price as soon
as possible.
Q: How do you ensure product quality?
A: We have TUV/SGS/ISO quality control systems and strictly adhere
to them. We have a professional quality inspection team, and each
packer conducts a final inspection according to the quality
inspection instructions before packaging.
Q: What is the delivery time?
A: Depending on the minimum order quantity, we ship within 10-15
business days after receiving the deposit. 20-foot container orders
typically take 30-35 days to fulfill.
Q: Besides filling machines, do you offer other conventional
firefighting equipment?
A: Of course. We offer a full range of professional firefighting
equipment, from sound and light alarms to smoke exhaust valves, as
well as FM200, CO2, and Novec1230 fire suppression systems. Feel
free to contact us!
Please inquire about the specific delivery time based on your order