API 661 Type C Forced Draft Air Cooler with SA179 Fin Tubes for Boiler Feed Systems(BFW)
|
API 661 Type C Forced Draft Air Cooler with SA179 Fin Tubes for Boiler Feed Systems(BFW) Forced Draft Type - Designed with tube bundles located on the discharge side of the fan. Category Parameter Value/Description ......
YUHONG HOLDING GROUP CO., LTD
|
API 661 Air Cooler Heat Exchanger For Oil Refinery Services
|
API 661 Air Cooler Heat Exchanger For Oil Refinery Services Scope of API 661 Applies to forced or induced draft air-cooled heat exchangers. Covers mechanical design, thermal performance, and operational requirements. Does not apply to: HVAC systems. ......
Yuhong Group Co.,Ltd
|
Air Cooler Induced Draft Fan High Pressure Large Air Flow Centrifugal Fan
|
Air Cooler Induced Draft Fan High Pressure Large Air Flow Industrial Fan 4-73 series boiler centrifugal fans are applicable to industrial boiler that burns a variety of media and equipped with devices to reduce smoke and dust. The conveying gas temp 250°C. The drive means of this fan has C-type and D-type two kinds with water-cool, bearing base and air......
Henan Dajing Fan Technology Co., Ltd.
|
Fin Tube Bundle Forced Draft Air Cooled Heat Exchanger With API And ASME Fabrication Code As Cooler And Condenser
|
...according to standard ASME SECTION VIII DIV I. Air cooling machine, with the environment air as the cooling medium, is the equipment to cool or condensate the process fluid with high temperature in the tube. It is called "air cooler" for short, and is also...
Dellok Yonghui Radiating Pipe Manufacturing Co.,Ltd.
|
High Efficiency Induced Draft Counter Flow Closed System Cooling Tower
|
... cooling tower) places a tubular heat exchanger inside the tower, and ensures the cooling effect through the heat exchange between the circulating air, spray water and circulating water. Because it is a closed cycle, it can ensure that the water quality is...
Wuxi Weishi Industrial Complete Equipment Co., Ltd.
|
Air Cooled L Type Finned tube in tube heat exchanger Al 1060 For Air Fin Coolers
|
Air Cooled L Type Finned tube in tube heat exchanger Al 1060 For Air Fin Coolers Aluminum L-Foot Finned Tubes are typically used in applications where temperatures do not exceed about 450 degrees F, primarily in air-cooled applications. Other examples include large radiators, such as large compressor oil coolers, and other forced-draft or induced-draft air......
Spezilla Tube Co., Ltd. (Shanghai)
|
Flat Bed Dry Cooler with 2.11 Fin Space
|
...°C to 150°C). We offer many options for air coolers including induced draft, forced draft, custom coil geometries and materials. We also offer a variety of fan and motor options - standard fans are direct drive propeller type, but other ......
Changzhou ADV Heat Exchanger Co., Ltd
|
Air Purification High Temperature Centrifugal Fan Overhang Type
|
... line chiller cooling, clinker cooler, circulating fluidized bed system, air purification and industrial waste gas treatment, flue gas desulfurization industrial boilers or incinerators forced draft/ induced draft/ primary/ secondary air, ventilation of...
Xinxiang SIMO Blower Co., Ltd.
|
