YJJ WDK-07 Electrochemical Oxygen Sensor Oxygen Battery Used for Measuring Oxygen Concentration In Medical Equipment
|
...Electrochemical Oxygen Sensor Oxygen Battery - Used for Measuring Oxygen Concentration In Medical Equipment Features: Oxygen Sensor Full-scale linear output Works without external power supply Temperature compensation Fast response Accurate and reliable Strong anti-interference ability Product Description The WDK-07 oxygen sensor is an electrochemical sensor specifically designed for measuring oxygen concentration...
ShenzhenYijiajie Electronic Co., Ltd.
|
KQT-O2 Electrochemical Oxygen Sensor
|
...the working electrode and the corresponding oxidation reaction of the anode material. The magnitude of the current is proportional to the concentration of oxygen. The concentration of oxygen can be determined by measuring the magnitude of the current. 2....
Xi'an Kacise Optronics Co.,Ltd.
|
Electrochemical Oxygen Sensor For Various Ventilators And Oxygen Concentrators OOM202 O2 Cell PB760 PB840 4OXV O2-A2
|
... Series Oxygen Sensor: OOM202-2S FROM STANDARD SENSORS TO CUSTOMIZED SENSORS Experienced Honeywell engineers work closely with customers to analyze their requirements when designing sensors for standard and OEM applications. Throughout the design process,...
Mengchuan Instrument Co,Ltd.
|
COVIDIEN Oxygen Sensor 10097559 Concentration Sensor For PB760 PB840 PB980 Series Ventilator Machine
|
COVIDIEN Oxygen Sensor 10097559 Concentration Sensor for PB760 PB840 PB980 Series Ventilator Machine Description Specification: Model: 10097559 Measurement Range: 0-100% oxygen Accuracy: ±2% full scale Output Signal: 10.0 to 14.0 mV in air Response Time......
China World Technology Medical Equipment Service Group
|
Ventilator Oxygen Sensor Medical , One Time Use O2 Sensor Medical ITG M-11
|
...: monitoring inhaled oxygen concentration in anesthesia breathing equipment Performance parameters: electrochemical principle; Measuring range: 0-100% oxygen concentration; Response time: < 12 seconds Wiring port: with 2 way AMP plug Operating temperature:...
Shenzhen Pray-med Technology Co.,Ltd
|
DSC380 Water Quality Dissolved Oxygen Sensor Optical Fluorescence DO Probe
|
... galvanic. Each type has its own advantages and disadvantages, and the cost varies accordingly. The electrochemical sensors are the most commonly used and have a moderate cost range. The cost of a basic electrochemical sensor can range from $50 to $150....
Xi'an Desun Uniwill Electronic Technology Co., Ltd.
|
ABS housing Medical Oxygen Sensor for Resmed Elisee150 MOX-20 Electrochemical O2 sensor
|
CITY MOX-20 Medical Oxygen Sensor for Resmed Elisee150 MOX-20 Electrochemical O2 sensor Specification of Medical oxygen sensor: Range 0-1500mBar Output Voltage 0.8-1.25V in air Measurement range 0 to 100% O2 Output connector Molex 3 pin Accuracy Within +/-......
Precise life group limited
|
Long Lifespan OOM102-1 Medical Oxygen Sensor With 3 Months Warranty
|
.... It is designed to provide accurate and reliable measurements of oxygen levels in various healthcare settings, ensuring patient safety and effective oxygen therapy. The OOM102-1 oxygen sensor utilizes advanced electrochemical technology to detect and...
Guangzhou YIGU Medical Equipment Service Co.,Ltd
|
Analog Type Analog Output Oxygen Sensor 4oxv O2-A2 SR-X2V with Customized OEM Support
|
... single-chip microcomputer. After the filtration operation inside the STM32 single-chip microcomputer, the oxygen concentration in the air is calculated and then output from the serial port. The module is compatible with 4OXV, Me2-O2, AAY80-390R and other...
Nanjing Kelisaike Safety Equipment Co., Ltd.
|
Multipurpose 02 Sensor Medical Practical MOX4 Oxygen Sensor
|
Multipurpose 02 Sensor Medical,Practical MOX4 Oxygen Sensor MOX4 OXYGEN SENSOR O2 sensor.pdf Operating Principle Partial pressure electrochemical Output 9 mV to 13 mV in 210 mBar O2 Measurement Range 0 mBar to 1500 mBar O2 Response Time <......
Med Accessories Technology Dongguan Co., Ltd.
|