Brand Name:HAOMAI Model Number:TTR-400 Place of Origin:China Transformer Turns Ratio Meter Model: TTR-400 Transformer Turns Ratio Meter TTR-400 is designed to measure the voltage ratio and turns ratio of singe phase or three-phase distribution transformers or power transformers in a substation or manufacturing environment according to test standard IEC 60076 and IEEE C57.12.90. Main Features ●Measures turns ratio, voltage ratio... |
HAOMAI ELECTRIC TEST EQUIPMENT CO.,LTD
|
|
|
Brand Name:Delta Model Number:CFRT Place of Origin:China IEC Standard Fully Automatic Transformer Turns Ratio Meter Introduction: IEC Standard Automatic Transformer Turns Ratio Meter Electric Cable Fire Resistance Testing Equipment is used for testing cables required to maintain circuit integrity when subject... |
Delta Technology (Chongqing) Co., Ltd.
Chongqing |
|
|
Brand Name:AI Model Number:TTR-I Place of Origin:China Mainland ...Transformer Turns Ratio Meter is designed according IEC76-1 and IEC60044. Transformer Turns Ratio Meter can be applied to test the turns ratio and group vector of single or three phase transformer. The connection group of three phase transformer also can be calculated with the ratio. All parameters can be measured in one test for three phase transformer. Functions: Parameters Testing / Type of Transformer... |
Advanced Instruments Co.,Limited
Hunan |
|
|
Brand Name:YUYANG Model Number:TTR-I Place of Origin:China ... for three phase transformer. The polarity measurement for single phase transformer or CT/PT Voltage ratio error calculation Current transformer ratio measurement Excitation current measurement in ratio testing Reproduction the AC test voltage from |
DONGGUAN YUYANG INSTRUMENT CO., LTD
Guangdong |
|
|
Brand Name:GFUVE Model Number:T-203H Place of Origin:BEIJING CHINA T-203H HANDHELD THREE PHASE TRANSFORMER TURNS RATIO TEST SET Description T-203H automatic transformer turns ratio tester adopts three-phase power supply output voltage, the test speed Instrument to adopt advanced technology for A/D, wide range range; High ... |
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing |
|
|
Brand Name:GDZX Model Number:ZXCBB Place of Origin:Hubei, China ...turn ratio accuracy, resolution and group ( including Z type) of the instrument transformer turn ratio testers with accuracy at 0.5 or below 0.05. It is composed of two parts: standard three phase PT and inductive voltage divider. The PT is used to test ratio group test function of the ratio tester, inductive voltage divider is used to test the accuracy and resolution of the ratio... |
Wuhan GDZX Power Equipment Co., Ltd
Hubei |
|
|
Brand Name:XZH TEST Model Number:XHBB128B Place of Origin:Xi'an, Shaanxi, China XHBB128B transformer turns ratio tester Introduction In the production process of semi-finished and finished power transformers, before the newly installed transformer is put into operation and according to the preventive test regulations of the Ministry... |
Xi'an Xu&Hui Electromechanical Technology Co., Ltd.
|
|
|
Brand Name:RISING Model Number:RSBC Place of Origin:China ...Transformer Turn Ratio Group Tester 3 Phase TTR Meter Product Description In power transformer in the production of semi-finished products and finished products, before the new installation of the transformer in operation and according to the national ministry of preventive test procedures, require the operation of transformer turn ratio or voltage ratio test, you can check the correctness of the transformer turn |
Wuhan Rising Electric Co., Ltd.
Hubei |
|
|
Brand Name:HNMC Model Number:MCTTR301 Place of Origin:China ...Transformer Turn Ratio Test Set MCTTR301 Main Features 1) LCD display 2) Measure single phase or three phase transformer turn ratio 3) Auto switch phase sequence and ranges 4) Auto calculate voltage regulation ratio 5) Ratio measurement & Ratio Error calculation by input standard ratio 6) Can test CT ratio and display excitation current 7) Group vector measurement; can auto measure single&three phase transformer... |
Zhengzhou Great Electric Co.,Ltd.
Henan |
|
|
Place of Origin:Wuhan Hubei China Brand Name:Huaying Model Number:Huaying Series 1. Product Name: Transformer Ratio Meter HYBC-901 2. Equipment Description: 1 The voltage ratio measurement for three or singe phase transformer 2 The group vector measurement for three phase transformer. 3 The polarity measurement for single phase ... |
Wuhan Huaying Electric Power Tech & Science Co.,ltd
Hubei |
|
|
Place of Origin:Wuhan,Hubei,China Brand Name:Huaying ...other transformers whose zero-load current is relatively high. The tester has wide testing range, fast testing speed, favorable repeatability, flexible ... |
Wuhan Huaying Electric Power Tech & Science Co.,ltd
Hubei |
|
|
Brand Name:KRE Model Number:KE8301F Place of Origin:China ... class below 0.2, and can test single phase meter if adding an isolation voltage transformer. Features: Meter positions can be chosen from 3 - 48 Integrated / separated aluminum alloy structure, light and reliable, flexible choices Auto protection of |
Guangzhou Kingrise Enterprises Co., Ltd.
Guangdong |
|
|
Brand Name:Shareway Model Number:MOX-LAN-QP4B-5004 Place of Origin:Guangdong,shenzhen .... Sealed bottom case design. RoHS NL peak solder rating of 235°C. Meets IEEE 802.3 & ANSI X3.263 standards. Wide range of package types to accommodate various designs. Operating temperature –20°C to +70°C. MSL = Moisture Sensitivity Level a |
SHAREWAY TECHNOLOGY CO., LTD.
|
|
|
Brand Name:Shinhom Model Number:HS0404 Place of Origin:China FEATURES: 1:1 Turns Ratio Compliant with IEEE802.3u and ANSI X.3.263 standards including 350 uH OCL with 8mA bias Soldering methods:Wave,Reflow Operating Temperature:0℃ to 70℃ Storage Temperature:-55℃ to 125℃ ELECTRONICAL SPECIFICATIONS : Turns ratio: N1:... |
Shaanxi Shinhom Enterprise Co.,Ltd
Shaanxi |
|
|
Place of Origin:China Brand Name:Xili Model Number:DT86 IEC Three Phase Electromechanical Energy Meter with ABS , Bakelite , PC Terminal cover IEC Three Phase Electromechanical Energy Meter Four wire The DT86 three-phase fore-wire meter is designed to meet the latest IEC62053-21,IEC62052-11 standards for measuring active energy in three-phase four-wire alternating current power grids. Connection is direct or by instrument transformers... |
Hangzhou xili watthour meter manufacture co.,ltd
Zhejiang |
|
|
Brand Name:Chuangyin Model Number:CY-RCT02-190 Place of Origin:China Clamp-on Rogowski Coil Current Transformer Red/Black Flexible Power Meters General data: .Ambient operating temp:-20……+70℃ .Ambient storage temp.:-25……+75℃ .Standard Safety:IEC 61010-1:2001,600V CATⅢ Specification: unit :mm Dimensions CY-RCT01-190 Window... |
Shenzhen Chuangyin Co., Ltd.
Guangdong |
|
|
Brand Name:HongCe Model Number:DL-30 Place of Origin:China ... error and phase displacement of current transformers. Standard: IEC 61869-2 Instrument transformers - Part 2: Additional requirements for current transformers Current Transformer Testing Equipment configuration: Current transformer tester, the product is |
Guangzhou HongCe Equipment Co., Ltd.
Guangdong |