| Sign In | Join Free | My benadorassociates.com |
|
All ratio and ct three phase transformer wholesalers & ratio and ct three phase transformer manufacturers come from members. We doesn't provide ratio and ct three phase transformer products or service, please contact them directly and verify their companies info carefully.
| Total 20 products from ratio and ct three phase transformer Manufactures & Suppliers |
|
|
|
Brand Name:GDZX Model Number:ZX-SBC Place of Origin:China ... of traditional transformer ratio bridge test. The screen adopts large screen high-resolution LCD, and the power supply adopts lithium battery, which is convenient for ... |
Wuhan GDZX Power Equipment Co., Ltd
Hubei |
|
|
Brand Name:YUYANG Model Number:TTR-I Place of Origin:China ... for three phase transformer. The polarity measurement for single phase transformer or CT/PT Voltage ratio error calculation Current transformer ratio measurement Excitation current measurement in ratio testing Reproduction the AC test voltage from |
DONGGUAN YUYANG INSTRUMENT CO., LTD
Guangdong |
|
|
Brand Name:AI Model Number:CPT-3 Place of Origin:China ...Transformer CT Analyzer CT Testing Equipment Tester for current transformer: 1.Excitation curve and parameters test 2.Turns ratio test 3. Ratio and phase error test 4. Polarity mark check 5. Coil resistance measurement 6. Secondary loop burden measurement 7. Error line curve test for protection CT 8. Transient CT parameters test 9. CT nameplate guess 10.Saturation hysteresis loop curve measurement Applications of CT Current Transformer |
Advanced Instruments Co.,Limited
Hunan |
|
|
Place of Origin:China Brand Name:Kingsine Model Number:KT200 ...-260 V, 47-63 Hz, 10 A(max.) Variable Ratio Measurement Range:1-5000, accuracy: ±0.1% Range:5000-10000, accuracy: ±0.2% Voltage Output 0-120 V(AC) Phase Measurement Accuracy: ±3 min, resolution:0.01 min Current Output 0-5 A(RMS) Peak value: 15 A |
Kingsine Electric Automation Co., Ltd.
Guangdong |
|
|
Brand Name:HAOMAI Model Number:CTP-200P Place of Origin:China Universal CT and PT Tester Model: CTP-200P The Universal CT and PT Tester CTP-200P is a lightweight field portable instrument designed to test CT and PT installed in a utility system. It can be used for many routine workshop tests, as well as field testing... |
HAOMAI ELECTRIC TEST EQUIPMENT CO.,LTD
|
|
|
Brand Name:IVY Model Number:IVY-CS-05-80A Place of Origin:Zhejiang ...Transformer 80A CT with Busbar Copper Sheet 1.Overview: ● DC Immunity with Better Phase Error ● Tooled Casing Instead of Traditional Tape ● Irregular Central Hole for Easy Assembly ● Various Busbar Integration to Adapt Application ● Widely used for energy meter, smart grid, generator, EV charger, switching cabinet, medical equipment, circuit protection, electrical machine 2.Specification: Current Ratio... |
IVY METERING CO.,LTD
Shanghai |
|
|
Brand Name:HNMC Model Number:MCTTR301 Place of Origin:China ...Transformer Turn Ratio Test Set MCTTR301 Main Features 1) LCD display 2) Measure single phase or three phase transformer turn ratio 3) Auto switch phase sequence and ranges 4) Auto calculate voltage regulation ratio 5) Ratio measurement & Ratio Error calculation by input standard ratio 6) Can test CT ratio and display excitation current 7) Group vector measurement; can auto measure single&three phase transformer... |
Zhengzhou Great Electric Co.,Ltd.
Henan |
|
|
Brand Name:GFUVE Model Number:GF1061 Place of Origin:China ... test 2. Transformation ratio test 2. Transformation ratio test 3. Polarity 3. Polarity 4. 5% and 10% error curve 4. Ratio error, phase error 5. Accuracy limiting factor (ALF) 5. Degauss 6. Degauss 6. Calculation of knee point value 7. Ratio error, |
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing |
|
|
Model Number:CPT-III Place of Origin:China ...Phase or Three Phase Current Transformer Tester Application: Tests for current transformer: Excitation curve and parameters test Turns ratio test Ratio and phase error test Polarity mark check Winding resistance measurement Secondary loop burden measurement Error line curve test for protection CT Transient CT parameters test CT nameplate guess Saturation hysteresis loop curve measurement Tests for voltage transformer: Turns ratio |
Delta Technology (Chongqing) Co., Ltd.
Chongqing |
|
|
Brand Name:XZH TEST Model Number:XHTX201D Place of Origin:Xi'an, Shaanxi, China ... Transformer CT/PT Analyzer Single Phase Excitation Ratio Testing Product Description XHTX201D CT/PT ANALYZER is mainly used for field testing of P class CT and PT. The test items mainly include excitation characteristic, transformation ratio, polarity... |
Xi'an Xu&Hui Electromechanical Technology Co., Ltd.
|
|
|
Place of Origin:Wuhan Hubei China Brand Name:Huaying Model Number:Huaying Series .... 3 The polarity measurement for single phase transformer or CT/PT 4 Voltage ratio error calculation 5 Current transformer ratio measurement 6 Excitation current measurement in ratio testing 7 Reproduction the AC test voltage from power source to |
Wuhan Huaying Electric Power Tech & Science Co.,ltd
Hubei |
|
|
Place of Origin:Wuhan,Hubei,China Brand Name:Huaying ...single phase transformer or CT/PT 4 Voltage ratio error calculation 5 Current transformer ratio measurement 6 Excitation current measurement in ratio testing 7 Reproduction the AC test voltage from power source to reduce the effects of bad power source 8 |
Wuhan Huaying Electric Power Tech & Science Co.,ltd
Hubei |
|
|
Brand Name:Acrel Model Number:AKH-0.66-K-24 150-300A/5A Place of Origin:China ...phase combined CT for ring net cabinet Split Core Type current transformers can be easily installed onto an existing power system without disconnecting the measured primary conductor. Customers will benefit from reduced labour intensity, lowered operating costs and improved work efficiency by using high mobility or space-constrained or uninterrupted power systems. Split core current transformer model Type Ratio... |
Jiangsu Acrel Electrical Manufacturing Co., LTD.
Jiangsu |
|
|
Brand Name:XG Model Number:JLSZV Place of Origin:XIAN,CHINA ...phase cast resin Combined Ct Pt Metering Unit 1. Parameter Technical Parameter – Voltage transformer Model Rated voltage ratio Accuracy class Rated output Ultimate output Rated insulating voltage JLSZV- 6kV 12kV 3000/100 0.2 0.5 15 30 300 3.6/25/40 6000/100 7.2/32/60 10000/100 12/42/75 Technical Parameter – Current transformer... |
Xi'an Xigao Electricenergy Group Co., Ltd.
Shanxi |
|
|
Brand Name:RISING Model Number:RSCT-201 Place of Origin:China ... for online measurement of primary current and secondary current size, conversion ratio, phase difference and polarity judgment of current transformers and transformers below 35kV.The product is composed of primary current clamp (high voltage detector), |
Wuhan Rising Electric Co., Ltd.
Hubei |
|
|
Place of Origin:China Brand Name:SUCHEN Model Number:DX-20 Product Description Product Description DX discription DX range of current transformers have been designed to be double terminal entry which allows short circuit links to be fitted when it is necessary to disconnect the measuring instrument from the ... |
YUEQING RENHE ELECTRIC CO., LTD.
|
|
|
Brand Name:HEMEI Model Number:HM-CTC1535 Place of Origin:China Split Core Current Transformer Clamp On Type The HM-CTC1535 is a high performance AC clamp on Current transformer with excellent transformation and low phase shift. The high quality magnetic core and uniform windings provide for accurate measurements up ... |
Hefei Hemei Electronics Technology Co., Ltd
Anhui |
|
|
Brand Name:GENY Model Number:YC2000A Place of Origin:CHINA ...High Precision 0.1% Single Phase Portable Standard Meter with Clamp Options Product Description High accuracy 0.3% External power supply r test lead power,suit for Fieldwork With 2pcs clamp CT to test ratio of current transformer. (Optional) Large size ... |
Guangzhou GENY Electric Co., Ltd
|