| Sign In | Join Free | My benadorassociates.com | 
 | 
| Categories | Air Handling Units | 
|---|---|
| Brand Name: | EuroKlimat | 
| Model Number: | EKDM | 
| Certification: | ISO9001, ISO14001, OHSAS18001, CRAA, CQC | 
| Place of Origin: | China | 
| MOQ: | 1 | 
| Price: | negotiation | 
| Payment Terms: | L/C, T/T | 
| Supply Ability: | 5,000pcs per month | 
| Delivery Time: | 15 working days after received your payment | 
| Packaging Details: | Plywood | 
| Product Name: | Humidifying (AHU) air handling units | 
| Installation: | Ceiling/floor installation | 
| Air Flow(m3/h): | 2,000-400,000 | 
| Aluminum Fins: | Shutter-type hyperbolic and hydrophilic fins | 
| Test Pressure (Mpa): | 3.3 | 
| Coils rows: | 4/6 | 
Humidifying (AHU) air handling units with backward fan high ESP
EKDM air flow range is from 1000m3/h to 400000m3/h. Available functional sections include fresh/return air mixing section, cooling section, heating section, primary/medium/high efficiency filter section, electric heating section, humidifying section, sound attenuation section, heat recovery section, secondary air-return section, fan section, air diffuser section etc. Different combinations can meet different air handling requirements.
• The surface of the unit is made of quality color steel, which can resist corrosion, scratch and ultraviolet radiation.
•    Internal panels are made of steel plates galvanized  with aluminum and zinc, with an assured  service life of more than 15 years. All panels  feature  end-to-end  joints and smooth surfaces, without any bur or corroded point.
•    The internal panels feature reinforced design, which is strong enough to support the largest  air handling unit.
•    The unit panel  has two thicknesses,  namely  30mm and 50mm.Inside  the panel, hermetically foamed polyurethane (no fluorine) with a density of 48kg/m3 is used as the heat- insulating material. The heat conductivity factor is less than 0.02W/m°C.
•    Each functional section of the unit is equipped  with a steel trough base, thus  ensuring  it is well supported,  easy to transport and assemble. The overall robustness of the unit meets the  standard of CEN2.
Humidifying section
The relative humidity of the air changes as areas and seasons change. Different operating conditions have different requirements on humidity. In dry areas and seasons, or in environment that requires high humidity, you may need to install a humidifier. Standard humidifiers for EKDM series units use dry steam. In addition, EK also provides high-pressure spray, wet film humidifying, electrode humidifying etc. If you have any special requirements on humidifying, please contact EK.
Humidifier Introduction
High-pressure spray humidifier—equal-enthalpy humidifying; water distribution pipes and nozzles made from stainless steel; high pressure spray; efficient, safe, reliable and energy saving.
Wet film humidifier— saturation efficiency; space-saving; reducing total length of the unit; no water handling; safe and reliable.
Dry steam humidifier—equal-temperature humidifying; high humidifying efficiency; made from stainless steel; graceful exterior; and corrosion proof.
Electrode humidifier—high humidifying efficiency; multiple control solutions to choose from.
Electric heating humidifier——efficient and accurate.
Humidifier Comparison
| Type of humidifier | Working conditions | ||||||
| Environment temp. (°C) | Humidity | Critical wind speed (m/s) | Water quality | Water/steam temp. (°C) | Water/steam pressure (MPa) | Length of humidifying section (mm) | |
| High-pressure spray humidifier | 1 ~ 40 | ≤ 85% | 0.5 ~ 3.5 | Tap water, purified water or water with similar quality | 4 ~ 55 | 0.1 ~ 0.5 | 960 | 
| Dry steam humidifier | -10 ~ 50 | / | 0.5 ~ 3.5 | Steam | 0<150 | 0.02 ~ 0.4 | 640 | 
| Wet film humidifier | 5 ~ 100 | < 90% | ≤ 4.0 | Tap water or water with similar quality | 5 ~ 40 | 0.15 ~ 0.75 | Can be installed together with cooling coil | 
| Electrode humidifier | 0 ~ 40 | < 85% | / | Clean tap water or softened water | 4 ~ 35 | 0.1 ~ 1.0 | 640 | 
| Electric heating humidifier | 0 ~ 40 | < 85% | / | Clean tap water, softened water or deionized water | 4 ~ 35 | 0.1 ~ 0.3 | 640 | 
Dry Steam Humidifier
Humidifiers should be chosen according to the control solution, steam pressure, required humidifying capacity and the width of the unit.
Dry Steam Humidifying Capacity Table
| model Nozzle Dia. | GZQ - 15 | GZQ -20 | GZQ -40 | GZQ -50 | |||||||
| Steam pressure | φ2 | φ4 | φ6 | φ8 | φ9 | φ10 | φ10.5 | φ12 | φ14 | φ16 | φ18 | 
| 0.02MPa | 1.5 | 4 | 9 | 22.5 | 27 | 34 | 40 | 55 | 75 | 145 | 187 | 
| 0.1MPa | 2.3 | 9.4 | 21.3 | 49.5 | 62 | 75.5 | 78 | 102 | 141 | 194 | 246 | 
| 0.2MPa | 3.6 | 14 | 35 | 68.5 | 106 | 131 | 142 | 160 | 216 | 311 | 397 | 
| 0.3MPa | 4.5 | 18.3 | 40 | 97.5 | 152 | 187 | 205 | 217 | 296 | 448 | 569 | 
| 0.4MPa | 6.1 | 24.5 | 58.5 | 124 | 196 | 227 | 250 | 275 | 375 | 590 | 760 | 
| Unit width | 4M | 5M | 6M | 7M | 8M | 9M | 10M | 11M | 12M | 13M | 14M | 
| Spout code | L3 | L3 | L4 | L4 | L5 | L5 | L6 | L6 | L7 | L7 | L8 | 
| Weight of Model 15 (kg) | 10 | 10 | 11 | 11 | 12 | 12 | 13 | 13 | 14 | 14 | 15 | 
| Weight of Model 20 (kg) | 12 | 12 | 13 | 13 | 14 | 14 | 15 | 15 | 16 | 16 | 17 | 
| Weight of Model 40 (kg) | 13 | 13 | 14 | 14 | 15 | 15 | 16 | 16 | 17 | 17 | 19 | 
| Weight of Model 50 (kg) | 14 | 14 | 15 | 15 | 16.5 | 16.5 | 18 | 18 | 19 | 19 | 21 | 
| Unit width | 15M | 16M | 17M | 18M | 19M | 20M | 21M | 22M | 23M ~ 26M | 
| Spout code | L8 | L9 | L9 | L10 | L10 | L11 | L11 | L12 | L13 | 
| Weight of Model 15 (kg) | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 
| Weight of Model 20 (kg) | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 
| Weight of Model 40 (kg) | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 
| Weight of Model 50 (kg) | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 
Wet film humidifier
Wet film humidifier humidifies the air through natural water evaporation. Its paper-like medium is made of macromolecule inorganic material which is highly hydrophilic. When dry air passes through the medium, water in the medium takes up heat in the air and evaporates to humidify the air. Wet film humidifier can use domestic water or tap water, and has the following advantages:
■ Clean humidification—no “white powder” produced during temperature drop
■ Humidifying distance—the thickness of the wet film itself
■ High saturation efficiency—up to 80%
■ Safe and reliable—the film material is mildew and bacteria proof, with a service life up to 8 ~ 10 years
■ Excellent cooling performance—cooling through filling-catalyzed direct evaporation; more efficient cooling with less space Wet-film Humidifying Capacity for Typical Units
| Model EKDM | Rated air flow m3/h | Fresh air conditions (kg/h) | Return air conditions (kg/h) | ||||||
| 35% efficiency | 60% efficiency | 75% efficiency | 85% efficiency | 35% efficiency | 60% efficiency | 75% efficiency | 85% efficiency | ||
| 306 | 2000 | 4 | 9 | 11 | 12 | 4 | 7 | 9 | 10 | 
| 406 | 3000 | 7 | 13 | 16 | 18 | 5 | 10 | 13 | 15 | 
| 407 | 4000 | 8 | 15 | 20 | 22 | 7 | 13 | 16 | 18 | 
| 408 | 5000 | 9 | 18 | 23 | 26 | 8 | 15 | 19 | 22 | 
| 508 | 6000 | 13 | 24 | 31 | 35 | 10 | 20 | 25 | 29 | 
| 607 | 7000 | 14 | 26 | 33 | 37 | 11 | 21 | 27 | 31 | 
| 608 | 8000 | 16 | 30 | 39 | 44 | 13 | 25 | 32 | 36 | 
| 511 | 9000 | 19 | 35 | 45 | 52 | 15 | 29 | 37 | 42 | 
| 610 | 10000 | 21 | 39 | 50 | 57 | 17 | 32 | 41 | 47 | 
| 611 | 12000 | 23 | 44 | 56 | 64 | 19 | 36 | 46 | 52 | 
| 712 | 15000 | 30 | 58 | 74 | 84 | 25 | 48 | 60 | 69 | 
| 812 | 18000 | 35 | 67 | 86 | 98 | 29 | 55 | 70 | 80 | 
| 813 | 20000 | 39 | 74 | 94 | 107 | 32 | 60 | 77 | 88 | 
| 915 | 25000 | 52 | 99 | 126 | 144 | 42 | 81 | 103 | 118 | 
| 1015 | 30000 | 60 | 114 | 145 | 166 | 49 | 93 | 119 | 136 | 
| 1313 | 35000 | 67 | 128 | 163 | 187 | 55 | 105 | 134 | 153 | 
| 1315 | 40000 | 79 | 150 | 191 | 219 | 64 | 123 | 157 | 179 | 
| 1515 | 45000 | 91 | 175 | 222 | 254 | 75 | 143 | 182 | 208 | 
| 1417 | 50000 | 97 | 185 | 237 | 271 | 80 | 153 | 194 | 222 | 
| 1520 | 60000 | 122 | 233 | 297 | 339 | 100 | 191 | 243 | 278 | 
| 1720 | 70000 | 139 | 266 | 338 | 386 | 114 | 218 | 277 | 316 | 
| 1722 | 80000 | 154 | 295 | 375 | 429 | 126 | 241 | 307 | 351 | 
| 1626 | 90000 | 173 | 332 | 422 | 482 | 142 | 272 | 346 | 395 | 
| 1826 | 100000 | 196 | 375 | 477 | 545 | 160 | 307 | 391 | 446 | 
Note: standard fresh air conditions: temperature of 28°C and relative humidity of 15%; mixed air conditions: containing 30% of fresh air.
Specifciations
| Model EKDM | Rated air flow m3/h | Windward area of coil (m2) | Air flow (m3/h) | Diameter of fan impeller mm | Fan performance | ||||
| 2.25 | 2.50 | 2.75 | 3.00 | Max. total pressure of fan Pa | Max. motor power kW | ||||
| m/s | m/s | m/s | m/s | ||||||
| 306 | 2000 | 0.23 | 1863 | 2070 | 2277 | 2484 | 160 | 1300 | 2.2 | 
| 406 | 3000 | 0.34 | 2754 | 3060 | 3366 | 3672 | 200 | 1300 | 3 | 
| 407 | 4000 | 0.41 | 3321 | 3690 | 4059 | 4428 | 225 | 1500 | 3 | 
| 408 | 5000 | 0.48 | 3888 | 4320 | 4752 | 5184 | 250 | 1800 | 5.5 | 
| 508 | 6000 | 0.65 | 5265 | 5850 | 6435 | 7020 | 280 | 1800 | 7.5 | 
| 607 | 7000 | 0.69 | 5589 | 6210 | 6831 | 7452 | 280 | 1800 | 7.5 | 
| 608 | 8000 | 0.81 | 6561 | 7290 | 8019 | 8748 | 315 | 1800 | 7.5 | 
| 511 | 9000 | 0.94 | 7614 | 8460 | 9306 | 10152 | 315 | 1800 | 11 | 
| 610 | 10000 | 1.05 | 8505 | 9450 | 10395 | 11340 | 355 | 2000 | 11 | 
| 611 | 12000 | 1.17 | 9477 | 10530 | 11583 | 12636 | 400 | 2000 | 15 | 
| 712 | 15000 | 1.55 | 12555 | 13950 | 15345 | 16740 | 450 | 2000 | 15 | 
| 812 | 18000 | 1.81 | 14661 | 16290 | 17919 | 19548 | 500 | 2000 | 18.5 | 
| 813 | 20000 | 1.98 | 16038 | 17820 | 19602 | 21384 | 500 | 2000 | 18.5 | 
| 915 | 25000 | 2.66 | 21546 | 23940 | 26334 | 28728 | 560 | 2000 | 22 | 
| 1015 | 30000 | 2.99 | 24219 | 26910 | 29601 | 32292 | 630 | 2000 | 30 | 
| 1313 | 35000 | 3.40 | 27540 | 30600 | 33660 | 36720 | 630 | 2000 | 30 | 
| 1315 | 40000 | 3.99 | 32319 | 35910 | 39501 | 43092 | 710 | 2000 | 30 | 
| 1515 | 45000 | 4.65 | 37665 | 41850 | 46035 | 50220 | 800 | 2000 | 37 | 
| 1417 | 50000 | 4.95 | 40095 | 44550 | 49005 | 53460 | 800 | 2000 | 45 | 
| 1520 | 60000 | 6.36 | 51516 | 57240 | 62964 | 68688 | 900 | 2000 | 45 | 
| 1720 | 70000 | 7.27 | 58887 | 65430 | 71973 | 78516 | 900 | 2000 | 55 | 
| 1722 | 80000 | 8.05 | 65205 | 72450 | 79695 | 86940 | 1000 | 2000 | 75 | 
| 1626 | 90000 | 9.01 | 72981 | 81090 | 89199 | 97308 | 1000 | 2000 | 75 | 
| 1826 | 100000 | 10.21 | 82701 | 91890 | 101079 | 110268 | 1120 | 2000 | 110 | 
| 1852 | 2000000 | 20.42 | 165402 | 183780 | 202158 | 220536 | 1120x2 | 2000 | 110x2 | 
| 3652 | 4000000 | 40.84 | 330804 | 367560 | 404316 | 441072 | 1120x4 | 2000 | 110x4 | 
Note:
■ This table only lists some typical models among many models for quick model selection.
■ Total fan pressures listed above are tested on standard fans with rated air flow.
■ External residual pressure = Total fan pressure - Internal resistance. For internal resistance of EKDM units.
|   | 
 4 / 6 / 8 Row Double Skin Return Air Handling Units For Schools / Hospitals
                                                                                    
                        
                        
                        
                                                            4 / 6 / 8 Row Double Skin Return Air Handling Units For Schools / Hospitals
                                                    
                        
                     High Efficiency Ceiling Hanging Double Skin Air Handling Unit 12-754KW
                                                                                    
                        
                        
                        
                                                            High Efficiency Ceiling Hanging Double Skin Air Handling Unit 12-754KW
                                                    
                        
                     Vertical Cabinet Type Chilled Water Return Air Handling Unit 23-429KW
                                                                                    
                        
                        
                        
                                                            Vertical Cabinet Type Chilled Water Return Air Handling Unit 23-429KW
                                                    
                        
                     50 mm PU Insulation Double Skin Modular Fresh Air Handling Unit With Heat Recovery Wheel
                                                                                    
                        
                        
                        
                                                            50 mm PU Insulation Double Skin Modular Fresh Air Handling Unit With Heat Recovery Wheel
                                                    
                        
                     Double Skin Clean Room AHU Return Air Handling Units Indoor Installation
                                                                                    
                        
                        
                        
                                                            Double Skin Clean Room AHU Return Air Handling Units Indoor Installation
                                                    
                        
                     Horizontal / Vertical Modular Residential Air Handling Units With 4 - 8 Row
                                                                                    
                        
                        
                        
                                                            Horizontal / Vertical Modular Residential Air Handling Units With 4 - 8 Row
                                                    
                        
                     Double Skin 1/2 Rows Heating Coil 7-1300kw Custom Air Handling Units Ith 30/50 Mm Insulation
                                                                                    
                        
                        
                        
                                                            Double Skin 1/2 Rows Heating Coil 7-1300kw Custom Air Handling Units Ith 30/50 Mm Insulation
                                                    
                        
                     Airport installation modular AHUs with KRUGER fan VFD max 800 tons
                                                                                    
                        
                        
                        
                                                            Airport installation modular AHUs with KRUGER fan VFD max 800 tons
                                                    
                        
                     Floor Standing Direct Expansion Air Handling Unit With Condenser 30000-60000m3h
                                                                                    
                        
                        
                        
                                                            Floor Standing Direct Expansion Air Handling Unit With Condenser 30000-60000m3h
                                                    
                        
                     100000m3/H Plug Fan Modular Air Handling Units For Hospital
                                                                                    
                        
                        
                        
                                                            100000m3/H Plug Fan Modular Air Handling Units For Hospital