| Sign In | Join Free | My benadorassociates.com | 
 | 
| Categories | Air Handling Units | 
|---|---|
| Brand Name: | EuroKlimat | 
| Model Number: | EKDM | 
| Certification: | ISO9001, ISO14001, OHSAS18001, CRAA, CQC | 
| Place of Origin: | China | 
| MOQ: | 1 | 
| Price: | negotiation | 
| Payment Terms: | L/C, T/T | 
| Supply Ability: | 5,000pcs per month | 
| Delivery Time: | 15 working days after received your payment | 
| Packaging Details: | Plywood | 
| Product Name: | Double skin Return air handling units | 
| Installation: | Ceiling/floor installation | 
| Cooling Capacity(kW): | 25-300 | 
| Heating Capacity(kW): | 28-330 | 
| Air Flow(m3/h): | 5000-60000 | 
| Aluminum Fins: | Shutter-type hyperbolic and hydrophilic fins | 
| Test Pressure (Mpa): | 3.3 | 
| Coils rows: | 4/6 | 
Double skin Return air handling units with 4-8 rows cooling coil air flow 2,000-400,000 m3h
EKDM air flow range is from 1000m3/h to 400000m3/h. Available functional sections include fresh/return air mixing section, cooling section, heating section, primary/medium/high efficiency filter section, electric heating section, humidifying section, sound attenuation section, heat recovery section, secondary air-return section, fan section, air diffuser section etc. Different combinations can meet different air handling requirements.
• The surface of the unit is made of quality color steel, which can resist corrosion, scratch and ultraviolet radiation.
• Internal panels are made of steel plates galvanized with aluminum
and zinc, with an assured service life of more than 15 years. All
panels feature end-to-end joints and smooth surfaces, without any
bur or corroded point.
• The internal panels feature reinforced design, which is strong
enough to support the largest air handling unit.
• The unit panel has two thicknesses, namely 30mm and 50mm.Inside
the panel, hermetically foamed polyurethane (no fluorine) with a
density of 48kg/m3 is used as the heat- insulating material. The
heat conductivity factor is less than 0.02W/m°C.
• Each functional section of the unit is equipped with a steel
trough base, thus ensuring it is well supported, easy to transport
and assemble. The overall robustness of the unit meets the standard
of CEN2.
Specifciations
| Unit model EKDM | Rated air flow m3/h | 4 rows | 6 rows | 8 rows | |||||||||
| Total cooling capacity kW | Water flow l/s | Water resi- stance kPa | Pipe diameter DN | Total cooling capacity kW | Water flow l/s | Water resi- stance kPa | Pipe diameter DN | Total cooling capacity kW | Water flow l/s | Water resi-stance kPa | Pipe diameter DN | ||
| 306 | 2000 | 12 | 0.5 | 6 | 40 | 16 | 0.7 | 15 | 40 | 18 | 0.8 | 26 | 40 | 
| 406 | 3000 | 17 | 0.8 | 7 | 40 | 23 | 1.1 | 16 | 40 | 27 | 1.3 | 27 | 40 | 
| 407 | 4000 | 23 | 1.1 | 13 | 40 | 31 | 1.5 | 32 | 40 | 36 | 1.7 | 51 | 40 | 
| 408 | 5000 | 29 | 1.4 | 20 | 40 | 38 | 1.8 | 48 | 40 | 42 | 2.0 | 29 | 40 | 
| 508 | 6000 | 36 | 1.7 | 20 | 40 | 48 | 2.3 | 48 | 40 | 52 | 2.5 | 23 | 50 | 
| 607 | 7000 | 39 | 1.9 | 17 | 40 | 53 | 2.5 | 38 | 40 | 61 | 2.8 | 58 | 50 | 
| 608 | 8000 | 47 | 2.2 | 24 | 40 | 62 | 3.0 | 58 | 40 | 68 | 3.2 | 26 | 50 | 
| 511 | 9000 | 57 | 2.7 | 57 | 40 | 70 | 3.3 | 37 | 40 | 78 | 3.8 | 31 | 50 | 
| 610 | 10000 | 64 | 3.1 | 51 | 40 | 76 | 3.6 | 29 | 50 | 89 | 4.3 | 51 | 50 | 
| 611 | 12000 | 70 | 3.4 | 20 | 40 | 92 | 4.4 | 44 | 50 | 103 | 5.0 | 38 | 50 | 
| 712 | 15000 | 90 | 4.3 | 23 | 50 | 119 | 5.8 | 55 | 65 | 131 | 6.3 | 44 | 65 | 
| 812 | 18000 | 107 | 5.2 | 27 | 65 | 141 | 6.8 | 60 | 65 | 157 | 7.6 | 51 | 65 | 
| 813 | 20000 | 121 | 5.8 | 34 | 65 | 151 | 7.3 | 40 | 65 | 167 | 8.2 | 31 | 65 | 
| 915 | 25000 | 158 | 7.5 | 51 | 65 | 196 | 9.3 | 53 | 65 | 214 | 10.2 | 38 | 80 | 
| 1015 | 30000 | 188 | 9.0 | 47 | 50 | 232 | 11.2 | 53 | 65 | 254 | 12.0 | 30 | 80 | 
| 1313 | 35000 | 208 | 10.0 | 32 | 65 | 262 | 12.6 | 37 | 65 | 304 | 14.4 | 59 | 65 | 
| 1315 | 40000 | 250 | 12.0 | 49 | 65 | 310 | 14.8 | 54 | 65 | 338 | 16.0 | 37 | 65 | 
| 1515 | 45000 | 286 | 14.0 | 53 | 65 | 352 | 17.0 | 58 | 65 | 386 | 18.6 | 41 | 65 | 
| 1417 | 50000 | 300 | 14.4 | 38 | 65 | 368 | 17.4 | 36 | 65 | 430 | 20.4 | 56 | 65 | 
| 1520 | 60000 | 380 | 18.0 | 49 | 80 | 464 | 22.4 | 38 | 65 | 516 | 25.2 | 33 | 65 | 
| 1720 | 70000 | 440 | 21.2 | 55 | 80 | 536 | 26.0 | 42 | 65 | 596 | 28.8 | 33 | 80 | 
| 1722 | 80000 | 464 | 22.0 | 25 | 80 | 616 | 29.2 | 55 | 65 | 688 | 33.2 | 45 | 80 | 
| 1626 | 90000 | 544 | 26.0 | 40 | 80 | 684 | 33.2 | 44 | 80 | 752 | 36.8 | 32 | 80 | 
| 1826 | 100000 | 608 | 28.8 | 42 | 80 | 760 | 36.4 | 45 | 80 | 832 | 40.0 | 33 | 80 | 
| 1852 | 200000 | 1216 | 57.6 | 40 | 80 | 1368 | 66.4 | 44 | 80 | 1504 | 73.6 | 32 | 80 | 
| 3652 | 400000 | 2432 | 115.2 | 40 | 80 | 2736 | 132.8 | 44 | 80 | 3008 | 147.2 | 32 | 80 | 
Note:
■ Temperature of cooled inlet water: 7°C; temperature drop 5°C.
■ Return air conditions for standard cooling operation: dry/wet
bulb temperature of inlet air: 27°C/19.5°C.
■ Coils are copper pipes with aluminum fins (12 fins/inch). EK can
provide coils with 8~14 fins/inch.
■ This table only lists the performance parameters of some typical
models among many models.
|   | 
 High Efficiency Ceiling Hanging Double Skin Air Handling Unit 12-754KW
                                                                                    
                        
                        
                        
                                                            High Efficiency Ceiling Hanging Double Skin Air Handling Unit 12-754KW
                                                    
                        
                     Vertical Cabinet Type Chilled Water Return Air Handling Unit 23-429KW
                                                                                    
                        
                        
                        
                                                            Vertical Cabinet Type Chilled Water Return Air Handling Unit 23-429KW
                                                    
                        
                     50 mm PU Insulation Double Skin Modular Fresh Air Handling Unit With Heat Recovery Wheel
                                                                                    
                        
                        
                        
                                                            50 mm PU Insulation Double Skin Modular Fresh Air Handling Unit With Heat Recovery Wheel
                                                    
                        
                     Double Skin Clean Room AHU Return Air Handling Units Indoor Installation
                                                                                    
                        
                        
                        
                                                            Double Skin Clean Room AHU Return Air Handling Units Indoor Installation
                                                    
                        
                     Horizontal / Vertical Modular Residential Air Handling Units With 4 - 8 Row
                                                                                    
                        
                        
                        
                                                            Horizontal / Vertical Modular Residential Air Handling Units With 4 - 8 Row
                                                    
                        
                     Double Skin 1/2 Rows Heating Coil 7-1300kw Custom Air Handling Units Ith 30/50 Mm Insulation
                                                                                    
                        
                        
                        
                                                            Double Skin 1/2 Rows Heating Coil 7-1300kw Custom Air Handling Units Ith 30/50 Mm Insulation
                                                    
                        
                     Airport installation modular AHUs with KRUGER fan VFD max 800 tons
                                                                                    
                        
                        
                        
                                                            Airport installation modular AHUs with KRUGER fan VFD max 800 tons
                                                    
                        
                     Humidifying HVAC Air Handling Unit With Backward Fan High ESP
                                                                                    
                        
                        
                        
                                                            Humidifying HVAC Air Handling Unit With Backward Fan High ESP
                                                    
                        
                     Floor Standing Direct Expansion Air Handling Unit With Condenser 30000-60000m3h
                                                                                    
                        
                        
                        
                                                            Floor Standing Direct Expansion Air Handling Unit With Condenser 30000-60000m3h
                                                    
                        
                     100000m3/H Plug Fan Modular Air Handling Units For Hospital
                                                                                    
                        
                        
                        
                                                            100000m3/H Plug Fan Modular Air Handling Units For Hospital