Sign In | Join Free | My benadorassociates.com
benadorassociates.com
Products
Search by Category
Home > Shoes Processing Services >

Plug Type Industrial Air Cooled Heat Exchanger Petrochemical And Oil Refineries Application

Categories Air Cooled Heat Exchanger
Brand Name: YUHONG
Model Number: Air Cooler 916C
Certification: ASME , U STAMP , PED, API , ABS, LR, DNV, GL , BV, KR, TS, CCS
Place of Origin: China
MOQ: 1 Set
Price: 2000 ~ 10M usd
Payment Terms: L/C, T/T
Supply Ability: 10000 tons/month
Delivery Time: 45---150 DAYS
Packaging Details: Pallet
Air Cooler Type: FORCED DRAFT
Air Cooler Standard: API 661, ASME SEC VIII Div-1
Air Cooler Header Material: ASTM A516 Gr.60
Air Cooler Header Type: Plug Type
Air Cooler Fin Tube Material: ASME SA179 25 X 3 X 9144MM
Air Cooler Fin Type: Embedd G Type : 0.4 X 15.875 X 3.17MM
Air Cooler Nozzle Material: ASME SA105 6" 150# ASME B16.5
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Plug Type Industrial Air Cooled Heat Exchanger Petrochemical And Oil Refineries Application

Air Cooler According to API 661 and ASME SEC VIII Div-1, Petrochemical and Oil Refineries Application


Advantages of Air Coolers in Oil Refineries:
1. Water Conservation: Unlike water-cooled systems, air coolers do not require large amounts of water.
2. Cost-Effective: Lower operational costs compared to water-cooled systems.
3. Environmental Friendly: No risk of water contamination or discharge.

Yuhong Group air cooler for an oil refinery is a critical piece of equipment used to cool process fluids, gases, or equipment in refinery operations. These coolers are essential for maintaining optimal temperatures, ensuring safety, and improving the efficiency of refining processes. Below is an overview of air coolers in oil refineries, including their types, applications, and key considerations:

Types of Air Coolers Be Used In Oil Refineries:
1. Forced Draft Air Coolers:
- Fans are located at the bottom, forcing air upward through the finned tubes.
- Suitable for high-temperature applications.
- Easier maintenance as fans are accessible.


2. Induced Draft Air Coolers:
- Fans are located at the top, pulling air through the finned tubes.
- Better air distribution and reduced hot air recirculation.
- Commonly used in refineries due to their efficiency.


3. Horizontal Air Coolers:
- Tubes are arranged horizontally, and air flows perpendicular to the tubes.
- Ideal for cooling large volumes of process fluids.


4. Vertical Air Coolers:
- Tubes are arranged vertically, and air flows upward or downward.
- Used in space-constrained areas.


5. V-Shaped or A-Frame Air Coolers:
- Tubes are arranged in a V-shape to maximize surface area.
- Compact design, suitable for high-capacity cooling.

Sr.
No.
Item DescriptionIncluded
in SOW
Excluded
or Client SOW
AENGINEERING & DESIGN
1Thermal Design 
2Mechanical Design as per codes for heat exchanger (API-661 & ASME SEC VIII Div-1) 
3Structural Design 
4Thermal design guarantee 
5Mechanical & Structural Design Guarantee 
6Submission of Drawings and Documentation 
7Raw material procurement / Manufacturing / Fabrication / Assembly 
8ASME U-Stamp Certification of the Tube Bundle 
9FEA (Finite Element Analysis) for Nozzle Load using Nozzle Pro Software of PRG. 
10Nozzle loads – 2 x as specified in API 661 
11Wind & Seismic Analysis as per applicable Specification 
12Manufacturer Data Book 
13Installation Operation & Maintenance Manual / Drawings 
14Unloading, Reloading, Movement, and Storage at Site 
15Field Mechanical Erection 
16Site Supervision (per diem rates) for Site Installation and Trial Run. 
17Third-Party Inspection charges for all incoming, in-process, final assembly, and testing. 
BMATERIAL PROCUREMENT & FABRICATION, SUPPLY
1Completely Assembled Tube Bundle as per enclosed drawing with tube support and air sealing 
2Vent and drain nozzles with blind flanges, gaskets, and hardware 
3MP connection nozzles with blind flanges, gaskets, and hardware 
4Blind flanges with gaskets and hardware for process nozzles. 
5Tube Bundle guards. 
6Tube bundle, fan and drive support structure consisting of columns, beams, bracings, and support brackets. 
7Steam coil Bundle (wherever applicable) 
8Accessories to facilitate header displacement due to thermal expansion of piping Sliding pad. 
9Nameplate and relevant supports 
10Lifting Lug for Bundle 
11Personnel protection on equipment wherever required 
12Process, vent and drain piping (as per RFQ drawings). 
13Gaskets and bolting for External Connections. 
14Louver (Manual / Auto type) - on top of Bundles only (wherever applicable) 
15Inlet and outlet Headers 
CSTRUCTURAL PARTS
1Supporting Steel Structure for tube bundles 
2Plenum Chamber for each fan complete with fan rings with removable fan guards as per Standard. 
3Header access platform/walkways with gratings, support beams, and handrails for header
maintenance -1000 mm wide on 2 sides only (as shown in drawing)
 
4Support structure for Drive Assembly 
5Earthing lugs 
6Insulation Cleats & Fire Proofing Cleats 
7Pipe Support Arrangement for Fire Fighting Lines 
8Distribution and collecting header as per drawings 
9Bolts, Studs & Nuts necessary for the complete assembly of the Units at Site. 
10Structural Support for Lighting Fixture 
DMECHANICAL COMPONENTS
1Axial Flow Fans Complete with
a. Fan (Manual) – type of fan as per applicable drawing
b. Driveshaft with bearings
c. Drive Pulley & Belt
d. Fan guard & screen
e. Provision of greasing for bearings
f. First fill of lubricant
 
2Louver for Applicable Tags 
3Steam coil for applicable tags 
4Standard Greasing points of each fan shaft bearings are accessible from floor level. 
5Anti-Rotation Device for all fans 
EELECTRICAL COMPONENTS
1Electrical Drive Motor - DOL Compatible.
Voltage = 380V
Motor rating = As per Drawings & Datasheets
Motor weather protection – Canopy only
 
2Motor Rating - CLASS 1, DIV 2, GROUP IIA/T3 or CLASS 1, DIV 2, GROUP IIC/T3 – As per drawings 
3Electrical Motor Cable Glands & Lugs 
4VFD for motors (50% of the fans considered with VFD operated for Applicable tags as per drawings). 
5Local Control Station (LCS) comprising of one push-button and ammeter for motors one at grade level
and one emergency stop push button at header platform level.
 
6Electrical Power & Control Cables, cable tray and support 
FINSTRUMENT COMPONENTS
1Vibration Switch -01 Nos. for Each Fan. 
2Cable Glands for All Instrument 
3Junction Box including Wiring Up to Junction Box. (If applicable) 
4Instruments cable Tray. 
5Support for Electrical and Instrumentation Cable Tray 
6Instruments as per Hook-up scheme for Auto Variable Pitch Fan & Pneumatic Louver Operations for applicable tags. (i.e., I/P Converter, Air Filter, Air Booster, Actuator, Tubing, etc.) 
7Requirement for AVP fan 
8Control panel for AVP fan 
GSURFACE PREPARATION & PAINTING
1Header BoxesPainting 
2Steel Support StructureHDG 
3Bundle C-Frame, Fan Guard, Wire Mesh, Gratings and Steel parts used in Tube Bundles and Drive AssemblyHDG 
4Fan Ring and Plenum ChamberHDG 
5Structural BoltingHDG 
6Hand Railing and LaddersPainting 
HSHOP TESTING
1Internal plan inspection and testing as per Approved Quality Assurance Plan 
2Performance Test (Noise, Vibration, Air Flow, Power Consumption) - 1 Bay per Item. 
3Structural Trial Fit-Up 
4PMI If applicable 
5PWHT as per code (If Applicable) 
6Hydro Test of Bundle 
IPACKING & TRANSPORTATION
1Export Packing & Loading on the truck / trailer 
2All necessary support for Transport and customs clearance 
4Transportation in Knock Down Condition to Site. 
5Loading, Unloading and Handling at Site 

Buy Plug Type Industrial Air Cooled Heat Exchanger Petrochemical And Oil Refineries Application at wholesale prices
Send your message to this supplier
 
*From:
*To: YUHONG HOLDING GROUP CO., LTD
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0